V020-E3-2 Omron, V020-E3-2 Datasheet - Page 164

no-image

V020-E3-2

Manufacturer Part Number
V020-E3-2
Description
Publications, Books
Manufacturer
Omron
Datasheet

Specifications of V020-E3-2

Lead Free Status / RoHS Status
na
4-8-6
Settings
Restrictions and Additional Settings for Thumbwheel Type Numeral Settings
148
Numeral Setting
Settings for Numeral Settings
The following settings are made for numeral settings during their creation with the
support tool. Note that restrictions apply to several of the settings made for thumb-
wheel type numeral settings.
S Referenced numeral memory table
S Number of digits in the input numerical value
S Upper/lower limits (Ver.5 direct connection only)
S Display attribute
There are the following restrictions and additional items to set when creating
thumbwheel type numeral settings.
S Number of input digits for positive values when there is a sign display
S Display size
This is because if an attempt is made to change the leftmost digit from 0 to 1, or
from 1 to 0, an upper/lower limit value check is always performed.
In order to avoid this, either set the values so that n..n ≦ m..m, or create another
touch switch and write values to the host when digits are carried up or down.
Set the number of the numeral memory table used to record the numerical value
input using the numeral setting function.
Set the number of digits in the numerical values that can be input. A maximum of
8 digits (total of integer and decimal fraction parts) can be set. However, if there
is a sign display, the maximum number of digits for negative values will be seven.
Set the upper limit and lower limit separately. The maximum number of digits in
the set values is eight (or seven if there is a sign display).
When the upper limit value and lower limit value are set as negative values, set
“F” as the eighth digit.
Example: Upper limit value or lower limit value is “--123” → F0000123.
Set attributes in the same way as for numeral display. For details, see Numerals
Which can be Displayed (page 127).
When a sign display is set for a thumbwheel type numeral setting, a maximum of
7 digits can be input for positive values.
One of two sizes can be selected: “small” in which each digit comprises two
touch switch units, and “medium”, in which each digit comprises three touch
switch units. Note that if “small” is selected the area in which the numerical value
is displayed is also the touch switch input area.
Section 4-8