Specifications of V020-E3-2

Lead Free Status / RoHS Status
na
2-1-2
24
Description of Parts and Settings
Operation Status DIP Switch Settings
Reference: S In addition to the DIP switches, set also the “communication type”, “host link
CAUTION: If the DIP switch settings have been changed when the NT20S is powered, reset
Set the NT20S operation status with the DIP switches located in the bottom right
corner on the rear side of the body.
the power to the NT20S. The changes with the DIP switches become effective only
after the power supply is reset.
S It may be necessary to change the DIP switch settings after installing the NT20S
Switch #
SW2-1
SW2-2
SW2-3
SW2-4
baud rate”, etc. at the memory switches when host link/NT link is used.
When using the RS-232C interface, set the “RS-232C communication condi-
tions” and other appropriate settings.
For these settings, refer to Section 3-5” Setting the Conditions of Communica-
tions with the Host by Using the Memory Switches” (page 75)
in an operation panel. Bear this in mind when deciding the installation position.
During work at the panel, take care to ensure that no metal scraps enter the unit.
Screen data forced initialize effective/ineffective
ON
[OFF]
Screen display language mode
[ON]
OFF
Switching to the System Menu enabled/disabled
ON
[OFF]
Reserved for system use
ON
[OFF]
The NT20S will start in a special RUN mode in which the screen
data memory is initialized. When it is started, the memory initial-
ization menu will be displayed. For the initialization procedure,
refer to Section 3-4 Initializing Memory (page 72).
The NT20S will start in normal RUN mode.
Messages are displayed in English.
The System Menu cannot be displayed. If an error occurs during
a start-up, the System Menu will be automatically displayed.
However, “transfer mode” cannot be entered.
The System Menu can be displayed.
Must always be OFF.
Function
[ ] indicates factory setting.