Example of PT Status Notify Bit Application
198
Notification of the Operating Status to the PC
S Timing of PT status notify bit notification
In the example below, the status of the NT20S is checked by PT status notify bit
notification.
S Settings with the support tool
S PC program
S Program operation
(1) When the PT operating status (contact 11215) is OFF (0), “1” (PT stopped) is
(2) When the PT operating status (contact 11215) is ON (1), “2” (PT running) is
11215
11215
The contents of the PT status notify area (PT → PC) are written to the PC when-
ever the status of the NT20S changes during operation.
Make the following setting with the support tool.
Create the following PC ladder program.
Allocated word for PT status notify area: CH0110
stored in DM0001.
stored in DM0001.
@MOV(21)
@MOV(21)
DM0001
DM0001
#0001
#0002
PT running
Word that stores the PT status
PT stopped
Word that stores the PT status
Section 5-5
(1)
(2)