R88A-CAU015S Omron, R88A-CAU015S Datasheet - Page 99

no-image

R88A-CAU015S

Manufacturer Part Number
R88A-CAU015S
Description
POWER CABLE 15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAU015S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Design and Installation
j Connecting Cables
2-76
FND-X06
Wire the noise filter as shown at the left in the following illustrations.
Use twisted-pair cables for the power supply cables whenever possible, or bind the cables.
Separate power supply cables and signal cables when wiring.
Used shielded cables for control cables and encoder cables.
All cables leaving the control panel must be wired in metal ducts or conduits with blades.
All power cables and encoder cables to the Servomotors must be 20 m or less.
Installation panel
Secondary
Primary
Main power supply and
control circuit power
supply
to X25
Good:
Contactor
Noise filter
0.5 m max.
AC power
Position Drivers
1
2
3
Twisted Wires
NF
E
Do not coat mount-
ing surface.
4
5
6
FND-X
R0
S0
Position
Driver
FND-X50H-
Installation panel
Secondary
Primary
Binding
0.5 m max.
AC power
Contactor
Noise filter
Position Drivers
NO:
Binding
Main power
supply
Control circuit
power supply
2
1
2
Do not coat mount-
ing surface.
NF
E
R
S
T
Position
Driver
Chapter 2
FND-X
4
5
6

Related parts for R88A-CAU015S