S25FL032P0XMFI011 Spansion Inc., S25FL032P0XMFI011 Datasheet - Page 24

no-image

S25FL032P0XMFI011

Manufacturer Part Number
S25FL032P0XMFI011
Description
IC 32M CMOS 3V 104MHZ SPI BUS INTERFACE
Manufacturer
Spansion Inc.
Datasheet

Specifications of S25FL032P0XMFI011

Cell Type
NOR
Density
32Mb
Access Time (max)
8ns
Interface Type
Serial (SPI)
Boot Type
Bottom/Top
Address Bus
1b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
SOIC W
Sync/async
Synchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
4M
Supply Current
38mA
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL032P0XMFI011
Manufacturer:
SPANSION
Quantity:
4 391
Part Number:
S25FL032P0XMFI011
Manufacturer:
SPANSION
Quantity:
20 000
Company:
Part Number:
S25FL032P0XMFI011
Quantity:
664
Company:
Part Number:
S25FL032P0XMFI011
Quantity:
5 974
Part Number:
S25FL032P0XMFI0119
Manufacturer:
SPAN
Quantity:
6 142
9.1
24
Read Data Bytes (READ)
The Read Data Bytes (READ) command reads data from the memory array at the frequency (f
the SCK input, with a maximum speed of 40 MHz. The host system must first select the device by driving CS#
low. The READ command is then written to SI, followed by a 3 byte address (A23-A0). Each bit is latched on
the rising edge of SCK. The memory array data, at that address, are output serially on SO at a frequency f
on the falling edge of SCK.
Figure 9.1
can start at any location of the memory array. The device automatically increments to the next higher address
after each byte of data is output. The entire memory array can therefore be read with a single READ
command. When the highest address is reached, the address counter reverts to 00000h, allowing the read
sequence to continue indefinitely.
The READ command is terminated by driving CS# high at any time during data output. The device rejects any
READ command issued while it is executing a program, erase, or Write Registers operation, and continues
the operation uninterrupted.
CS#
SCK
SI
SO
Mode 3
Mode 0
Hi-Z
and
Table 9.1 on page 23
0
1
Command
2
Figure 9.1 Read Data Bytes (READ) Command Sequence
3
4
5
6
detail the READ command sequence. The first address byte specified
S25FL032P
7
MSB
23 22 21
8
D a t a
9
24 Bit Address
10
3 2 1 0
S h e e t
28
29
30
31 32 33 34 35 36 37 38 39
MSB
7 6 5
S25FL032P_00_05 October 5, 2009
Data Out 1
4
3 2 1 0 7
R
) presented at
Data Out 2
R
,

Related parts for S25FL032P0XMFI011