Specifications of STM32W108HBU6
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Processing Unit
Microprocessor
Operating Supply Voltage (min)
1.18V
Operating Supply Voltage (typ)
1.25V
Operating Supply Voltage (max)
1.32V
Package Type
VFQFPN EP
Pin Count
40
Mounting
Surface Mount
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
STM32W108HBU63
Manufacturer:
ST
Quantity:
201
Company:
Part Number:
STM32W108HBU64TR
Manufacturer:
TDK
Quantity:
30 000
General-purpose timers
10.1.6
Figure 33. PWM input mode timing
120/208
PWM input mode
This mode is a particular case of input capture mode. The procedure is the same except:
●
●
●
For example, to measure the period in the TIMx_CCR1 register and the duty cycle in the
TIMx_CCR2 register of the PWM applied on TI1, use the following procedure depending on
CK_INT frequency and prescaler value:
●
●
●
●
●
●
●
Two ICy signals are mapped on the same TIy input.
These two ICy signals are active on edges with opposite polarity.
One of the two TIyFP signals is selected as trigger input and the slave mode controller
is configured in reset mode.
Select the active input for TIMx_CCR1: write the TIM_CC1S bits to 01 in the
TIMx_CCMR1 register (TI1 selected).
Select the active polarity for TI1FP1, used both for capture in the TIMx_CCR1 and
counter clear, by writing the TIM_CC1P bit to 0 (active on rising edge).
Select the active input for TIMx_CCR2by writing the TIM_CC2S bits to 10 in the
TIMx_CCMR1 register (TI1 selected).
Select the active polarity for TI1FP2 (used for capture in the TIMx_CCR2) by writing the
TIM_CC2P bit to 1 (active on falling edge).
Select the valid trigger input by writing the TIM_TS bits to 101 in the TIMx_SMCR
register (TI1FP1 selected).
Configure the slave mode controller in reset mode by writing the TIM_SMS bits to 100
in the TIMx_SMCR register.
Enable the captures by writing the TIM_CC1E and TIM_CC2E bits to 1 in the
TIMx_CCER register.
Doc ID 16252 Rev 7
STM32W108CB, STM32W108HB