Specifications of STM32W108HBU6

Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Processing Unit
Microprocessor
Operating Supply Voltage (min)
1.18V
Operating Supply Voltage (typ)
1.25V
Operating Supply Voltage (max)
1.32V
Package Type
VFQFPN EP
Pin Count
40
Mounting
Surface Mount
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STM32W108HBU6
Manufacturer:
ST
0
Part Number:
STM32W108HBU61TR
Manufacturer:
ST
0
Part Number:
STM32W108HBU63
Manufacturer:
ST
Quantity:
201
Part Number:
STM32W108HBU63TR
Manufacturer:
ST
0
Part Number:
STM32W108HBU64
Manufacturer:
ST
0
Part Number:
STM32W108HBU64TR
Manufacturer:
TDK
Quantity:
30 000
Part Number:
STM32W108HBU64TR
Manufacturer:
ST
0
STM32W108CB, STM32W108HB
10.3.7
31
15
Reserved
30
14
Bits [1:0] TIM_CC3S: Capture / Compare 3 Selection
Bit 13 TIM_CC4P: Capture/Compare 4 output Polarity
Bit 12 TIM_CC4E: Capture/Compare 4 output Enable
Timer x capture/compare enable register (TIMx_CCER)
Address offset: 0xE020 (TIM1) and 0xF020 (TIM2)
Reset value:
TIM_C
Bit 9 TIM_CC3P
Bit 8 TIM_CC3E
C4P
29
13
rw
This configures the channel as an output or an input. If an input, it selects the input source.
00: Channel is an output.
01: Channel is an input and is mapped to TI3.
10: Channel is an input and is mapped to TI4.
11: Channel is an input and is mapped to TRGI. This requires an internal trigger input selected
by the TIM_TS bit in the TIM_SMCR register.
Note: TIM_CC3S may be written only when the channel is off (TIM_CC3E = 0 in the
If CC4 is configured as an output channel:
0: OC4 is active high.
1: OC4 is active low.
If CC4 configured as an input channel:
0: IC4 is not inverted. Capture occurs on a rising edge of IC4. When used as an external
trigger, IC4 is not inverted.
0: IC4 is inverted. Capture occurs on a falling edge of IC4. When used as an external trigger,
IC4 is inverted.
1: Capture is enabled.
If CC4 is configured as an output channel:
0: OC4 is disabled.
1: OC4 is enabled.
If CC4 configured as an input channel:
0: Capture is disabled.
1: Capture is enabled.
Refer to the CC4P description above.
Refer to the CC4E description above.
TIM_C
C4P
28
12
rw
TIMx_CCER register).
27
11
Reserved
0x0000 0000
26
10
TIM_C
C3P
25
rw
9
Doc ID 16252 Rev 7
TIM_C
C3P
24
rw
8
Reserved
23
7
Reserved
22
6
TIM_C
C2P
21
rw
5
TIM_C
C2P
20
rw
4
General-purpose timers
19
3
Reserved
18
2
TIM_C
C1P
17
rw
1
149/208
TIM_C
C1P
16
rw
0

Related parts for STM32W108HBU6