EP2AGX190FF35C6N Altera, EP2AGX190FF35C6N Datasheet - Page 233

no-image

EP2AGX190FF35C6N

Manufacturer Part Number
EP2AGX190FF35C6N
Description
IC ARRIA II GX 190K 1152FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX190FF35C6N

Number Of Logic Elements/cells
181165
Number Of Labs/clbs
7612
Total Ram Bits
9939
Number Of I /o
612
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
190300
# I/os (max)
612
Frequency (max)
400MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
190300
Ram Bits
10380902.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX190FF35C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX190FF35C6N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX190FF35C6N
0
Chapter 9: Configuration, Design Security, and Remote System Upgrades in Arria II GX Devices
Fast Passive Parallel Configuration
Table 9–4. FPP Timing Parameters for Arria II GX Devices with Decompression and Design Security not Enabled
Figure 9–5. FPP Configuration Timing Waveform with Decompression or Design Security Enabled
Notes to
(1) Use this timing waveform when the decompression and/or design security features are used.
(2) The beginning of this waveform shows the device in user-mode. In user mode, nCONFIG, nSTATUS, and CONF_DONE are at logic-high levels.
(3) After power up, the Arria II GX device holds nSTATUS low for the time of the POR delay.
(4) After power up, before and during configuration, CONF_DONE is low.
(5) Do not leave DCLK floating after configuration. You can drive it high or low, whichever is more convenient.
(6) DATA[7..1] are available as user I/O pins after configuration. The state of these pins depends on the dual-purpose pin settings. DATA[0] is
(7) If required, you can pause DCLK by holding it low. When DCLK restarts, the external host must provide data on the DATA[7..0] pins prior to
(8) Two DCLK falling edges are required after CONF_DONE goes high to begin the initialization of the device.
© July 2010
CONF_DONE
t
t
t
t
Notes to
(1) Use these timing parameters when the decompression and design security features are not used.
(2) This value is obtainable if you do not delay configuration by extending the nCONFIG or nSTATUS low pulse width.
(3) The minimum and maximum numbers apply only if you chose the internal oscillator as the clock source for initializing the device.
(Note 1)
Symbol
CD2UM
CD2CU
CD2UMC
nSTATUS (3)
When nCONFIG is pulled low, a reconfiguration cycle begins.
a dedicated pin that is used for both the passive and active configuration modes and is not available as a user I/O pin after configuration.
sending the first DCLK rising edge.
Figure
INIT_DONE
Table
DATA[7..0]
(4)
nCONFIG
(Part 2 of 2)—Preliminary
User I/O
Input fall time
CONF_DONE high to user mode
CONF_DONE high to CLKUSR enabled
CONF_DONE high to user mode with CLKUSR option on
Altera Corporation
DCLK
9–5:
9–4:
t
t
CF2CD
CFG
Figure 9–5
device or microprocessor as an external host. This waveform shows timing when the
decompression and/or design security features are enabled.
t
CF2ST1
t
CF2ST0
t
CF2CK
t
ST2CK
t
STATUS
t
High-Z
DSU
1
Parameter
shows the timing waveform for FPP configuration when using a MAX II
2
Byte 0
t
DH
3
(3)
4
1
t
CH
2
Byte 1
t
CLK
t
t
CL
DH
3
4
(7)
t
4 × maximum
CD2CU
DCLK period
Minimum
CLKUSR
Byte 2
period)
1
+ (8532 ×
55
Byte (n-1)
3
Arria II GX Device Handbook, Volume 1
Maximum
(8)
4
150
40
Byte n
(Note
t
CD2UM
1),
(2)
(5)
(6)
Units
s
ns
User Mode
User Mode
9–13

Related parts for EP2AGX190FF35C6N