KIT_TC1797_SK Infineon Technologies, KIT_TC1797_SK Datasheet - Page 156

no-image

KIT_TC1797_SK

Manufacturer Part Number
KIT_TC1797_SK
Description
KIT STARTER AUDO FUTURE TC1797
Manufacturer
Infineon Technologies
Series
Audo Futurer
Type
MCUr

Specifications of KIT_TC1797_SK

Contents
Board, Adapters, Cables, CD, Power Supply
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
TC1797
Other names
KITTC1797SKIN
Data Sheet
all VDDP ), are internally directly connected. It is recommended that the power pins
of the same voltage are driven by a single power supply.
The PORST signal may be deactivated after all VDD5, VDD3.3, VDD1.5, and VAREF
power-supplies and the oscillator have reached stable operation, within the normal
operating conditions.
At normal power down the PORST signal should be activated within the normal
operating range, and then the power supplies may be switched off. Care must be
taken that all Flash write or delete sequences have been completed.
At power fail the PORST signal must be activated at latest when any 3.3 V or 1.5 V
power supply voltage falls 12% below the nominal level. The same limit of 3.3 V-12%
applies to the 5 V power supply too. If, under these conditions, the PORST is
activated during a Flash write, only the memory row that was the target of the write
at the moment of the power loss will contain unreliable content. In order to ensure
clean power-down behavior, the PORST signal should be activated as close as
possible to the normal operating voltage range.
In case of a power-loss at any power-supply, all power supplies must be powered-
down, conforming at the same time to the rules number 2 and 4.
Although not necessary, it is additionally recommended that all power supplies are
powered-up/down together in a controlled way, as tight to each other as possible.
Aditionally, regarding the ADC reference voltage VAREF:
– VAREF must power-up at the same time or later than VDDM, and
– VAREF must power-down eather earlier or at latest to satisfy the condition
VAREF < VDDM + 0.5 V. This is required in order to prevent discharge of VAREF
filter capacitance through the ESD diodes through the VDDM power supply. In
case of discharging the reference capacitance through the ESD diodes, the
current must be lower than 5 mA.
152
Electrical Parameters
V1.1, 2009-04
TC1797