LH28F160BVE-BTL90 Sharp Electronics, LH28F160BVE-BTL90 Datasheet - Page 13

no-image

LH28F160BVE-BTL90

Manufacturer Part Number
LH28F160BVE-BTL90
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F160BVE-BTL90

Cell Type
NOR
Density
16Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
21/20Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
0C to 70C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
2M/1M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LH28F160BVE-BTL90
Manufacturer:
OSRAM
Quantity:
1 000
Part Number:
LH28F160BVE-BTL90
Manufacturer:
SHARP
Quantity:
1 000
Part Number:
LH28F160BVE-BTL90
Manufacturer:
SHARP
Quantity:
1 000
Part Number:
LH28F160BVE-BTL90
Manufacturer:
SHARP
Quantity:
20 000
SHARP
2. X=Any valid address within the device.
3. SRD=Data read from status register. See Table 7 for a description of the status register bits.
4. Following the Read Identifier Codes command, read operations access manufacturer and device codes. See Section 4.2 for
5. If the block is boot block, WP# must be at V,, or RP# must be at V,,
6. Either 40H or 10H are recognized by the WSM as the word/byte write setup.
7. Commands other than those shown above are reserved by SHARP for future device implementations and should not be
1. BUS operations are defined in Table 3.1 and Table 3.2.
VOTES:
Write Resume
IA=Identifier
BA=Address within the block being erased. The each block can select by the address pin A,, through A,, combination.
WA=Address
WD=Data to be written at location WA. Data is latched on the rising edge of WE# or CE# (whichever goes high first).
ID=Data read from identifier codes.
read identifier code data.
operations. Attempts to issue a block erase or word/byte write to a boot block while WP# is V,, or RP# is V,,.
used.
Code Address: see Figure 4. A-, set to V,, or V,, in Byte Mode (BYTE#=Vt,).
of memory location to be written.
Bus Cycles
Rea’d.
Table 4. Command Definitions(7)
Notes
LHF16V09
Over(‘)
First Bus Cycle
1 Addr(*)
Datac3)
to enable block erase or word/byte
Oper(l)
Second Bus Cycle
Addr(*)
Data(3)
Rev. 1.1
write
11

Related parts for LH28F160BVE-BTL90