IC LINE INTERFACE UNIT 640-PBGA

IDT82P2821BHG

Manufacturer Part Number
IDT82P2821BHG
Description
IC LINE INTERFACE UNIT 640-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82P2821BHG

Function
Line Interface Unit (LIU)
Interface
E1, J1, T1
Number Of Circuits
1
Voltage - Supply
1.8V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
*
Includes
Defect and Alarm Detection, Driver Over-Current Detection and Protection, LLOS Detection, PRBSARB / IB Detection and Generation
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Power (watts)
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
800-1703
82P2821BHG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2821BHG
Manufacturer:
IDT
Quantity:
170
Part Number:
IDT82P2821BHG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
LOOP - Loopback Control Register
Address: 019H, 059H, 099H, 0D9H, 119H, 159H, 199H, 1D9H, (CH1~CH8)
Type: Read / Write
Default Value: 00H
Programming Information
IDT82P2821
7 - 4
Bit
3
2
1
0
219H, 259H, 299H, 2D9H, 319H, 359H, 399H, 3D9H, (CH9~CH16)
419H, 459H, 499H, 4D9H, 519H, (CH17~CH21)
7D9H (CH0)
7
-
AUTOLP
Name
DLP
RLP
ALP
-
6
-
Reserved.
This bit determines whether automatic Digital/Remote Loopback is enabled.
0: Automatic Digital/Remote Loopback is disabled. (default)
1: Automatic Digital/Remote Loopback is enabled. The corresponding channel will enter Digital/Remote Loopback when the acti-
vate IB code is detected in the transmit/receive path for more than 5.1 sec.; and will return from Digital/Remote Loopback when
the deactivate IB code is detected in the transmit/receive path for more than 5.1 sec.
This bit controls whether Digital Loopback is enabled.
0: Disable. (default)
1: Enable.
This bit controls whether Remote Loopback is enabled.
0: Disable. (default)
1: Enable.
This bit controls whether Analog Loopback is enabled.
0: Disable. (default)
1: Enable.
5
-
4
-
21(+1) CHANNEL HIGH-DENSITY T1/E1/J1 LINE INTERFACE UNIT
105
AUTOLP
3
Description
DLP
2
RLP
1
February 6, 2009
ALP
0