• TXRDY: Transmit Ready Interrupt Flag
0 = DACC is not ready to accept new conversion requests.
1 = DACC is ready to accept new conversion requests.
• EOC: End of Conversion Interrupt Flag
0 = no conversion has been performed since the last DACC_ISR read.
1 = at least one conversion has been performed since the last DACC_ISR read.
• ENDTX: End of DMA Interrupt Flag
0 = the Transmit Counter Register has not reached 0 since the last write in DACC_TCR or DACC_TNCR.
1 = the Transmit Counter Register has reached 0 since the last write in DACC _TCR or DACC_TNCR
• TXBUFE: Transmit Buffer Empty
0 = the Transmit Counter Register has not reached 0 since the last write in DACC_TCR or DACC_TNCR.
1 = the Transmit Counter Register has reached 0 since the last write in DACC _TCR or DACC_TNCR.