FDC37C665IR SMSC Corporation, FDC37C665IR Datasheet - Page 79

no-image

FDC37C665IR

Manufacturer Part Number
FDC37C665IR
Description
3/5 Volt Advanced High-Performance Multi-Mode Parallel Port Super I/O Floppy Disk Controller with Infranred Support
Manufacturer
SMSC Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37C665IR
Manufacturer:
SMC
Quantity:
108
Part Number:
FDC37C665IR
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
FDC37C665IR
Manufacturer:
SMC
Quantity:
20 000
LINE CONTROL REGISTER (LCR)
Address Offset = 3H, DLAB = 0, READ/WRITE
This register contains the format information of
the serial line. The bit definitions are:
Bits 0 and 1
These two bits specify the number of bits in
each transmitted or received serial character.
The encoding of bits 0 and 1 is as follows:
The Start, Stop and Parity bits are not included
in the word length.
Bit 2
This bit specifies the number of stop bits in each
transmitted or received serial character.
following table summarizes the information.
Note:
beyond the first, regardless of the number used
in transmitting.
Bit 3
Parity Enable bit. When bit 3 is a logic "1", a
parity bit is generated (transmit data) or
BIT 2
0
1
1
1
1
The receiver will ignore all stop bits
BIT 1
WORD LENGTH
0
0
1
1
5 bits
6 bits
7 bits
8 bits
BIT 0 WORD LENGTH
--
0
1
0
1
5 Bits
6 Bits
7 Bits
8 Bits
NUMBER OF
STOP BITS
1.5
1
2
2
2
The
79
checked (receive data) between the last data
word bit and the first stop bit of the serial data.
(The parity bit is used to generate an even or
odd number of 1s when the data word bits and
the parity bit are summed).
Bit 4
Even Parity Select bit. When bit 3 is a logic "1"
and bit 4 is a logic "0", an odd number of logic
"1"'s is transmitted or checked in the data word
bits and the parity bit. When bit 3 is a logic "1"
and bit 4 is a logic "1" an even number of bits is
transmitted and checked.
Bit 5
Stick Parity bit. When bit 3 is a logic "1" and bit
5 is a logic "1", the parity bit is transmitted and
then detected by the receiver in the opposite
state indicated by bit 4.
Bit 6
Set Break Control bit. When bit 6 is a logic "1",
the transmit data output (TXD) is forced to the
Spacing or logic "0" state and remains there
(until reset by a low level bit 6) regardless of
other transmitter activity. This feature enables
the Serial Port to alert a terminal in a
communications system.
Bit 7
Divisor Latch Access bit (DLAB). It must be set
high (logic "1") to access the Divisor Latches of
the Baud Rate Generator during read or write
operations.
access the Receiver Buffer Register, the
Transmitter Holding Register, or the Interrupt
Enable Register.
MODEM CONTROL REGISTER (MCR)
Address
READ/WRITE
This 8 bit register controls the interface with the
MODEM or data set (or device emulating a
MODEM). The contents of the MODEM control
register are described below.
Offset
It must be set low (logic "0") to
=
4H,
DLAB
=
X,

Related parts for FDC37C665IR