xr17v258 Exar Corporation, xr17v258 Datasheet - Page 21

no-image

xr17v258

Manufacturer Part Number
xr17v258
Description
66mhz Pci Bus Octal Uart With Power Management Support
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr17v258IV
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr17v258IV-F
Manufacturer:
EXAR
Quantity:
295
Part Number:
xr17v258IV-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr17v258IV-F
Manufacturer:
XILINX
0
Part Number:
xr17v258IV-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Part Number:
xr17v258IVTR-F
Manufacturer:
Exar Corporation
Quantity:
10 000
xr
REV. 1.0.0
TIMERCNTL [7:0] Register
The bits [3:0] of this register are used to issue commands. The commands are self-clearing, so reading this
register does not show the last written command. Reading this register returns a value of 0x01 when the Timer
interrupt is enabled and there is a pending Timer interrupt. It returns a value of 0x00 at all other times. The
default settings of the Timer, upon power-up, a hardware reset or upon the issue of a ’Timer Reset’ command
are:
TIMER OPERATION
The following paragraphs describe the operation of the 16-bit Timer/Counter. The following conventions will be
used in this discussion:
Timer Operation in One-Shot Mode:
In the one-shot mode, the Timer output will stay HIGH when started (default state) and will continue to stay
HIGH until it times out (reaches the terminal count of ‘N’ clocks), at which time it will become LOW and stay
LOW. If the Timer is re-started before the Timer times out, the counter is reset and the Timer will wait for
another time-out period before setting its output LOW (See
Timer does not have any effect and a ’Stop Timer’ command needs to be issued first which will set the Timer
output to its default HIGH state. The Timer must be programmed while it is stopped since the following
operations are blocked after the Timer has been started:
TIMERCNTL [7:4]
TIMERCNTL [3:0]
Timer Interrupt Disabled
Re-triggerable mode selected
Internal crystal oscillator outputs selected as clock source
Timer output not routed to MPIO[0]
Timer stopped
’N’ is the 16-bit value programmed in the TIMER MSB, LSB registers
P +Q = N, where ’P’ and ’Q’ are approximately half of ’N’.
If N is even, P = Q = N/2.
If N is odd, P = (N – 1)/2 and Q = (N + 1)/2.
‘N’ can take any value from 0x0002 to 0xFFFF.
Any write to TIMER MSB, LSB registers
Issue of any command other than ’Start Timer’, ’Stop Timer’ and ’Reset Timer’
Reserved
These bits are used to invoke a series of commands that control the function of the Timer/Counter.
The commands 1100 to 1111 are reserved.
0001: Enable Timer Interrupt
0010: Disable Timer Interrupt
0011: Select One-shot mode
0100: Select Re-triggerable mode
0101: Select Internal Crystal Oscillator output as clock input for the Timer
0110: Select External Clock input through the TMRCK pin for the Timer
0111: Route Timer output to MPIO[0] pin
1000: De-route Timer output from MPIO[0]
1001: Start Timer
1010: Stop Timer
1011: Reset Timer
66MHZ PCI BUS OCTAL UART WITH POWER MANAGEMENT SUPPORT
T
ABLE
10: TIMER CONTROL R
21
Figure 7
EGISTERS
). If the Timer times out, re-starting the
XR17V258