PEB2085 SIEMENS [Siemens Semiconductor Group], PEB2085 Datasheet - Page 221

no-image

PEB2085

Manufacturer Part Number
PEB2085
Description
ISDN SubscribernAccess Controller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2085-P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
ALLEGRO
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
LNFINEON
Quantity:
20 000
Part Number:
PEB2085N V2.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB2085NV1.1
Manufacturer:
PHI
Quantity:
399
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS
Quantity:
5 967
Part Number:
PEB2085NV2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085P
Quantity:
41
Part Number:
PEB2085P
Manufacturer:
SIEMENS
Quantity:
1 000
BAS
CODR
CIC0
Note:
4.2.3
Value after reset: 3C
RSS
Semiconductor Group
Bus Access Status
Indicates the state of the TIC-bus:
0: the ISAC-S itself occupies the D and C/I channel
1: another device occupies the D and C/I channel
C/I Code Receive
Value of the received Command/Indication code. A C/I code is loaded in CODR only
after being the same in two consecutive IOM frames and the previous code has been
read from CIRR.
(refer to chapter 3.3.2)
C/I Code Change
A change in the received Command/Indication code has been recognized. This bit is
set only when a new code is detected in two consecutive IOM frames. It is reset by a
read of CIRR.
The BAS and CODR bits are updated every time a new C/I code is detected in two
consecutive IOM frames.
If several consecutive codes are detected and CIRR is not read, only the first and the
last C/I code (and BAS bit) is made available in CIRR at the first and second read of
that register, respectively.
Reset Source Select
Only valid if the terminal specific functions are activated (STCR:TSF).
0 :
7
Command/Indication Transmit RegisterCIXR
RSS
– a falling edge on the EAW line (External Subscriber Awake)
– a C/I code change (Exchange Awake).
signal, just as the SPU-bit (SPCR) does.
Subscriber or Exchange Awake
As reset source serves:
A logical zero on the EAW line activates also the IOM-interface clock and frame
BAC
H
CODX
221
Write
TCX
Register Description
ECX
Address 31
0
H

Related parts for PEB2085