7.2 Register 0: Control Register
7.2.1 Reset (bit 0.15)
ICS1893CK-40, Rev. C, 06/02/09
Table 7-5
of the ICS1893CK-40.
Note:
Table 7-5. Control Register (Register 0 [0x00]
† Whenever the PHY address of
‡ As per the IEEE Std 802.3u, during any write operation to any bit in this register, the STA must write the default value
This bit controls the software reset function. Setting this bit to logic one initiates an ICS1893CK-40 software
reset during which all Management Registers are set to their default values and all internal state machines
are set to their idle state. For a detailed description of the software reset process, see
“Software
During reset, the ICS1893CK-40 leaves bit 0.15 set to logic one and isolates all STA management register
accesses. However, the reset process is not complete until bit 0.15 (a Self-Clearing bit), is set to logic zero,
which indicates the reset process is terminated.
0.15
0.14
0.13
0.12
0.11
0.10
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Bit
to all Reserved bits.
The Control Register is accessible through the MII Management Interface.
Its operation is independent of the MAC Interface configuration.
It is fully compliant with the ISO/IEC Control Register definition.
Is equal to 00000 (binary), the Isolate bit 0.10 is logic one.
Is not equal to 00000, the Isolate bit 0.10 is logic zero.
Reset
Loopback enable
Data rate select
Auto-Negotiation enable
Low-power mode
Isolate
Auto-Negotiation restart
Duplex mode
Collision test
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
IEEE reserved
For an explanation of acronyms used in
lists the bits for the Control Register, a 16-bit register used to establish the basic operating modes
ICS1893CK-40 Data Sheet - Release
Reset”.
Definition
Copyright © 2009, Integrated Device Technology, Inc.
Table
No effect
Disable Loopback mode
10 Mbps operation
Disable Auto-Negotiation Enable Auto-Negotiation
Normal power mode
No effect
Half-duplex operation
No effect
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
Always 0
No effect
7-16:
When Bit = 0
All rights reserved.
46
Table
7-5, see
Isolate ICS1893CK-40
ICS1893CK-40 enters
Reset mode
Enable Loopback mode
100 Mbps operation
Low-power mode
from MII
Restart Auto-Negotiation
Full-duplex operation
Enable collision test
N/A
N/A
N/A
N/A
N/A
N/A
N/A
When Bit = 1
Chapter 1, “Abbreviations and
Chapter 7 Management Register Set
cess
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Ac-
RO
RO
RO
RO
RO
RO
RO
Section 4.1.2.3,
SC
SC
SF
Acronyms”.
fault
0/1†
De-
0‡
0‡
0‡
0‡
0‡
0‡
0‡
0
1
1
0
0
0
June 2009
0
0
0/4†
Hex
3
0
0

Related parts for 1893CKLFT