PCA9629PW,118 NXP Semiconductors, PCA9629PW,118 Datasheet - Page 9

no-image

PCA9629PW,118

Manufacturer Part Number
PCA9629PW,118
Description
Motor / Motion / Ignition Controllers & Drivers I2C-bus Stepper motor controller
Manufacturer
NXP Semiconductors
Type
Stepper Motor Controllerr
Datasheet

Specifications of PCA9629PW,118

Rohs
yes
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
4.5 V to 5.5 V
Supply Current
6 mA
Mounting Style
SMD/SMT
Package / Case
TSSOP-16
Factory Pack Quantity
2500
NXP Semiconductors
PCA9629
Product data sheet
7.3.2 SUBADR1 to SUBADR3 — I
7.3.3 ALLCALLADR — All Call I
Table 7.
Legend: * default value.
Subaddresses are programmable through the I
E4h, E8h, and the device(s) will not acknowledge these addresses right after power-up
(the corresponding bits [3:1] in MODE register is equal to 0).
Once subaddresses have been programmed to their right values, bits [3:1] (MODE
register) must be set to logic 1 in order to have the device acknowledging these
addresses. Only the seven MSBs representing the I
LSB in SUBADRx register is a read-only bit (0). When subaddress control bits [3:1] in
MODE register is set to logic 1, the corresponding I
during either an I
Table 8.
Legend: * default value.
The All Call I
same time (bit 0 in register MODE must be equal to 1 (power-up default state)). This
address is programmable through the I
read or write sequence. Only the seven MSBs representing the All Call I
are valid. The LSB in ALLCALLADR register is a read-only bit (0). If bit 0 in MODE
register = 0, the device does not acknowledge the address programmed in register
ALLCALLADR.
Address
01h
02h
03h
Address
04h
Register
SUBADR1
SUBADR2
SUBADR3
Register
ALLCALLADR
SUBADR1 to SUBADR3 - I
(addresses 01h, 02h 03h) bit description
ALLCALLADR - All Call I
2
C-bus address allows all the PCA9629s on the bus to be programmed at the
All information provided in this document is subject to legal disclaimers.
2
C-bus read or write sequence.
Rev. 1 — 29 February 2012
Bit
7:1
0
7:1
0
7:1
0
Bit
7:1
0
2
Symbol
A1[7:1]
A1[0]
A2[7:1]
A2[0]
A3[7:1]
A3[0]
C-bus address
2
Symbol
AC[7:1]
AC[0]
C-bus subaddress 1 to 3
2
C-bus address register (address 04h) bit description
2
C-bus subaddress registers 1 to 3
2
C-bus and can be used during either an I
Access Value
R/W
R only
R/W
R only
R/W
R only
Access Value
R/W
R only
2
C-bus. Default power-up values are E2h,
Fm+ I
2
1110 001*
0*
1110 010*
0*
1110 100*
0*
2
C-bus subaddress can be used
1110 000*
0*
C-bus subaddress are valid. The
2
C-bus stepper motor controller
I
I
I
Description
reserved
reserved
reserved
2
2
2
Description
ALLCALL I
address register
reserved
C-bus subaddress 1
C-bus subaddress 2
C-bus subaddress 3
PCA9629
© NXP B.V. 2012. All rights reserved.
2
C-bus address
2
C-bus
2
C-bus
9 of 51