FPS100024 TDK Corporation, FPS100024 Datasheet - Page 43

PWR SUP FNT END 24V 960W 40A

FPS100024

Manufacturer Part Number
FPS100024
Description
PWR SUP FNT END 24V 960W 40A
Manufacturer
TDK Corporation
Series
FPSr
Type
Commercialr
Datasheets

Specifications of FPS100024

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 40A
Size / Dimension
1.61" L x 5" W x 11.4" H (40.9mm x 127mm x 289.6mm)
Power (watts) - Rated
960W
Operating Temperature
0°C ~ 70°C
Efficiency
86%
Approvals
CE, EN, UL
Line Regulation
0.4%
Load Regulation
0.8%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
40A
Power Rating
960W
Input Voltage
85V AC - 265V AC / 120V DC To 360V DC.
Brand/series
FPS1000 Series
Configuration
Enclosed
Operation
Linear
Output
24 VDC @ 40 A
Power, Output
960 W
Primary Type
AC-DC
Special Features
High Efficiency, Hot Swappable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 360 VAC/VDC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1237

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FPS100024
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/P
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/PS
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/S
Manufacturer:
TDK-LAMBDA
Quantity:
232
CHAPTER 16
Notes:
*1: The Output of all the FPS1000 modules are floating in the rack.
*2: For input voltage lower than 100Vac, maximum output power derated by 10% of the power rating.
*3: For cases where conformance to to various safety standards (UL, EN etc.) is required, to be described
*4: Remote sensing can compensate up to 1V drop on each load wire.
*5: Not apllicable for units with I
*6: Factory default: ON/OFF_1 P.S. is On when AC is applied.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
1
2
3
4
5
6
7
8
9
as 100-240Vac (50/60Hz).
Number of power supply modules
Maximum output power
Input voltage / frequency range
Maximum input current (at 100/200Vac)
AC input connector
Output terminals
Remote sensing
Parallel operation
Series operation
Remote On/Off control
DC_OK signal
AC fail signal
Over Temperature alarm signal
Vout voltage trimming
Auxiliary power supply
Operating temperature
Storage temperature
Operating humidity
Storage humidity
Vibration
Shock
Applicable safety standards
Withstand voltage
Insulation resistance
Weight (Typ)
Size (W*H*D)
Warranty
FPS-T1U RACK SPECIFICATIONS
2
C bus option.
(*1)
(*2)
(*3)
(*4)
(*5)
(*6)
Kg
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Yr
W
A
V
Possible, via separate control for each FPS1000 unit .Refer to Instruction Manual.
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground:
Possible. Up to 3 racks with max 8FPS 1000 units of the same voltage and current rating.
Separate control for each FPS 1000 unit , By electrical signal or dry contact
Possible. Up to 3x FPS1000 units of the same voltage and current rating
11.2~12.5VDC.Maximum output current:0.25A, for each FPS1000 unit.
FPS-T1U :IEC inlet for each power supply module . FPS-T1U/P :None
More than 100Mohm at 25°C and 70% RH. Output-Ground: 500Vdc
Separate control for each FPS1000 unit, Open collector signal.
Separate control for each FPS1000 unit ,Open collector signal.
Separate control for each FPS1000 unit ,Open collector signal.
40
On/Off logic is user selectable. Refer to instruction manual.
On when Vout >80% +/-5%. Max.sink current: 10mA
0~50°C: 100% load. Derate 2%/°C, 50°C to 60°C.
85~265Vac continuous, 47~63Hz, Single phase
440x44x351mm. Refer to Outline Drawing.
12.0/6.0 for each FPS1000 unit installed
Bus-bars.Refer to outline drawing.
Maximum 3 x FPS1000 modules.
10~90% RH, no condensation.
10~95% RH, no condensation.
Refer to Instruction Manual
Refer to Instruction Manual
Built to meet ETS 300 019
Built to meet ETS 300 019
UL60950-1, EN60950-1
1414Vdc, 1min.
Two Years
Possible.
-30~85°C
3000
3.7

Related parts for FPS100024