FPS100024 TDK Corporation, FPS100024 Datasheet - Page 45

PWR SUP FNT END 24V 960W 40A

FPS100024

Manufacturer Part Number
FPS100024
Description
PWR SUP FNT END 24V 960W 40A
Manufacturer
TDK Corporation
Series
FPSr
Type
Commercialr
Datasheets

Specifications of FPS100024

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 40A
Size / Dimension
1.61" L x 5" W x 11.4" H (40.9mm x 127mm x 289.6mm)
Power (watts) - Rated
960W
Operating Temperature
0°C ~ 70°C
Efficiency
86%
Approvals
CE, EN, UL
Line Regulation
0.4%
Load Regulation
0.8%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
40A
Power Rating
960W
Input Voltage
85V AC - 265V AC / 120V DC To 360V DC.
Brand/series
FPS1000 Series
Configuration
Enclosed
Operation
Linear
Output
24 VDC @ 40 A
Power, Output
960 W
Primary Type
AC-DC
Special Features
High Efficiency, Hot Swappable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 360 VAC/VDC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1237

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FPS100024
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/P
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/PS
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPS100024/S
Manufacturer:
TDK-LAMBDA
Quantity:
232
17.7.3 Making the load connections
wires for load connection at the FPS-T1U.
17.7.4 Rear panel description
Fig. 17-1: FPS-T1U Rear panel
1. Mounting brackets. Use M6x12 screws to fix the FPS-T1U to the rack.
2. Output voltage terminals rugged busbars. Use M5x12 screws for load wires recommended
3. Micro-Fit 3.0
4. Ground stud M4 (three place).
5. IEC320 AC inlet ,shown for FPS-T1U. For FPS-T1U/P there are no IEC320 inlets on the rack.
The load wires should be properly terminated with terminals securely attached. DO NOT use unterminated
1
Tightening torque 24~31 Kgf.cm.
2
TM
Module C
Dual Row Right Angle 16pins (Molex) connector for control and monitoring signals.
3
Hazardous voltages may exist at the outputs and the load connections
when using a power supply with a rated output greater than 40V. To
protect personnel against accidental contact with hazardous voltages,
ensure that the load and it's connections has no accessible live parts.
Ensure that the load wiring insulation rating is greater than or equal to
the maximum output voltage of the power supply.
4
5
Module B
!
42
WARNING
Module A
1

Related parts for FPS100024