DS26524DK Maxim Integrated Products, DS26524DK Datasheet - Page 169

no-image

DS26524DK

Manufacturer Part Number
DS26524DK
Description
KIT DESIGN FOR DS26524
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS26524DK

Main Purpose
Telecom, Framer and Line Interface Units (LIUs)
Utilized Ic / Part
DS26524
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 5: Receive FIFO Overrun (ROVR).
Bit 4: Receive HDLC Opening Byte Event (RHOBT).
Bit 3: Receive Packet-End Event (RPE).
Bit 2: Receive Packet-Start Event (RPS).
Bit 1: Receive FIFO Above High Watermark Set Event (RHWMS).
Bit 0: Receive FIFO Not Empty Set Event (RNES).
0 = interrupt masked
1 = interrupt enabled
0 = interrupt masked
1 = interrupt enabled
0 = interrupt masked
1 = interrupt enabled
0 = interrupt masked
1 = interrupt enabled
0 = interrupt masked
1 = interrupt enabled
0 = interrupt masked
1 = interrupt enabled
7
0
RIM5
Receive Interrupt Mask Register 5 (HDLC)
0A4h + (200h x n): where n = 0 to 3, for Ports 1 to 4
6
0
ROVR
5
0
RHOBT
169 of 273
0
4
RPE
3
0
RPS
2
0
RHWMS
1
0
RNES
0
0

Related parts for DS26524DK