DS26524DK Maxim Integrated Products, DS26524DK Datasheet - Page 174

no-image

DS26524DK

Manufacturer Part Number
DS26524DK
Description
KIT DESIGN FOR DS26524
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS26524DK

Main Purpose
Telecom, Framer and Line Interface Units (LIUs)
Utilized Ic / Part
DS26524
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Note: All bits in this register are real-time (not latched).
Bit 3: Receive Remote Alarm Indication Condition (RRAI). Set when a remote alarm is received at RTIP and
RRING.
Bit 2: Receive Alarm Indication Signal Condition (RAIS). Set when an unframed all-ones code is received at
RTIP and RRING.
Bit 1: Receive Loss of Signal Condition (RLOS). Set when 192 consecutive zeros have been detected after the
B8ZS/HDB3 decoder.
Bit 0: Receive Loss of Frame Condition (RLOF). Set when the DS26524 is not synchronized to the received
data stream.
7
0
RRTS1
Receive Real-Time Status Register 1
0B0h + (200h x n): where n = 0 to 3, for Ports 1 to 4
6
0
5
0
174 of 273
0
4
RRAI
3
0
RAIS
2
0
RLOS
1
0
RLOF
0
0