Specifications of STEVAL-IFS003V1

Design Resources
STEVAL-IFS003V1 Gerber Files STEVAL-IFS003V1 Schematic STEVAL-IFS003V1 Bill of Materials
Sensor Type
Temperature
Sensing Range
-55°C ~ 125°C
Interface
I²C
Voltage - Supply
7.5 V ~ 19 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST72F651, STDS75, STLM75
Silicon Manufacturer
ST Micro
Silicon Core Number
STLM75/STDS75 And ST72F651AR6
Kit Application Type
Sensing - Temperature
Application Sub Type
Temperature Sensor
Kit Contents
Board
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-6238
15 DEVICE CONFIGURATION AND ORDERING INFORMATION
Each device is available for production in user pro-
grammable versions (FLASH). FLASH devices are
shipped to customers with a default content (FFh).
This implies that FLASH devices have to be con-
figured by the customer using the Option Bytes.
15.1 OPTION BYTE
The option byte allows the hardware configuration
of the microcontroller to be selected.
The option byte has no address in the memory
map and can be accessed only in programming
mode (for example using a standard ST7 program-
ming tool). The default content of the FLASH is
fixed to FFh. This means that all the options have
“1” as their default value.
OPT7 = Reserved. Must be kept at 1.
OPT6 = PE5PU I/O Port PE5 Pull-up Option
This option bit determines if a pull-up is connected
on Port E5.
0: Pull up present on PE5
1: No pull-up on PE5
When PE5PU=00, (also refer to
– For input, software can enable or disable the
– For output, the pull-up is enabled when Open
pull-up by programming PEOR.5 and PED-
DR.5=0.
Drain is selected by programming PEOR.5= and
PEDDR.5=1.
7
-
PE5
PU
MOD1
PS
MOD0
PS
-
WDG
Table
SW
USB
38):
EN
Doc ID 7215 Rev 4
FMP_
R
0
Table 38. PE5PU Options
OPT5:4 = PSMOD[1:0] Power Supply Mode
These option bits configure the power supply
mode. Refer to
Table 39. Power supply bits
OPT3 = Reserved. Must be kept at 1.
OPT2= WDG SW Hardware or software watchdog
This option bit selects the watchdog type.
0: Hardware (watchdog always enabled)
1: Software (watchdog to be enabled by software)
OPT1 = USBEN
0: USBEN alternate function disabled. Port F4 is
1: USBEN alternate function enabled on Port F4
OPT0= FMP_R Flash memory read-out protection
Readout protection, when selected provides a pro-
tection against program memory content extrac-
tion and against write access to Flash memory.
This protection is based on read and a write pro-
tection of the memory in test modes and IAP.
Input floating
Output Open Drain
with Pull-up
Input with pull-up
Output push pull
Input floating
Output Open Drain
Input floating
Output push pull
Forced Stand-
alone mode
Normal Dual-
Supply mode
Forced USB
mode
free for general purpose I/O
(function controlled by hardware)
Configuration
Mode
Table 39
Detector
Voltage
Ignored
Ignored
Read
USB
OPTION
PE5PU
0
1
for more information.
Not Started
Determined
by detector
Started
value
PLL
PEOR.5
0
0
1
1
0
0
1
1
ST72651AR6
OPT5 OPT4
0
1
x
PEDDR.5
153/161
0
1
0
1
0
1
0
1
0
1
0