EMULATOR E10A-USB SUPERH RISC

HS0005KCU04H

Manufacturer Part Number
HS0005KCU04H
Description
EMULATOR E10A-USB SUPERH RISC
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheet

Specifications of HS0005KCU04H

Contents
Emulation Module
For Use With/related Products
SH7205, SH7265
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5.7.5
When [Clear] is selected from the popup menu, the trace buffer that stores the trace information
becomes empty. If several [Trace] windows are open, all [Trace] windows will be cleared as they
all access the same buffer.
5.7.6
Select [Save...] from the popup menu to open the [Save As] file dialog box, which allows the user
to save the information displayed in the [Trace] window as a text file. A range can be specified
based on the [PTR] number (saving the complete buffer may take several minutes). Note that this
file cannot be reloaded into the [Trace] window.
Note: In filtering of trace information, the range to be saved cannot be selected. All the trace
5.7.7
The [Editor] window corresponding to the selected trace record can be displayed in the following
two ways:
• Select a trace record and choose [View Source] from the popup menu.
• Double-click a trace record.
The [Editor] or [Disassembly] window opens and the selected line is marked with a cursor.
5.7.8
Choose [Trim Source] from the popup menu to remove the white space from the left side of the
source.
When the white space is removed, a check mark is shown to the left of the [Trim Source] menu.
To restore the white space, choose [Trim Source] while the check mark is shown.
Rev. 2.00 Nov. 19, 2009 Page 130 of 294
REJ10J1766-0200
information displayed in the [Trace] window after filtering will be saved. Select a filtering
range on the [General] page in the [Trace Filter] dialog box if you want to save the
selected range. For details on the filtering function, refer to section 5.7.10, Extracting
Records from the Acquired Information.
Clearing the Trace Information
Saving the Trace Information in a File
Viewing the [Editor] Window
Trimming the Source