B.2.4 Installing/Replacing the Backup-Battery Board
An optional pluggable backup-battery board is available from Rabbit Semiconductor.
To install the backup-battery board, align the battery board over the outline as shown in
Figure B-5, and plug it in. Be careful to align the connectors and the backup battery board.
Fasten the backup board using a 4-40 × 3/16 screw and lockwasher.
To replace the backup-battery board, remove the screw and unplug the old battery board.
Then install a replacement backup-battery board.
Do not attempt to recharge the old battery and do not dispose of it in regular trash to avoid
any risk of explosion or fire. You may either return the old backup battery board to Rabbit
Semiconductor for recycling or send the battery yourself to an approved recycling facility.
Getting Started
NOTE: Before replacing the backup-battery board, make sure that the TCP/IP Develop-
ment Board is receiving power from the standard power supply. This makes sure that
data in RAM are not lost when the battery backup board is removed temporarily.
Figure B-5. Installing Backup Battery Board