S912XEP100J5MAG Freescale Semiconductor, S912XEP100J5MAG Datasheet - Page 874

no-image

S912XEP100J5MAG

Manufacturer Part Number
S912XEP100J5MAG
Description
MCU 64K FLASH 144-LQFP
Manufacturer
Freescale Semiconductor
Series
HCS12r
Datasheet

Specifications of S912XEP100J5MAG

Core Processor
HCS12X
Core Size
16-Bit
Speed
50MHz
Connectivity
CAN, EBI/EMI, I²C, IrDA, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
119
Program Memory Size
1MB (1M x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
1.72 V ~ 5.5 V
Data Converters
A/D 24x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 125°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S912XEP100J5MAG
Manufacturer:
FREESCALE
Quantity:
962
Part Number:
S912XEP100J5MAG
Manufacturer:
FREESCALE
Quantity:
2 400
Part Number:
S912XEP100J5MAG
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
S912XEP100J5MAG
Manufacturer:
FREESCALE
Quantity:
2 400
Part Number:
S912XEP100J5MAG
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
S912XEP100J5MAGR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Chapter 24 128 KByte Flash Module (S12XFTM128K2V1)
Once command must not be executed from the Flash block containing the Program Once reserved field to
avoid code runaway.
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
The reserved nonvolatile information register accessed by the Program Once command cannot be erased
and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index
values for the Program Once command range from 0x0000 to 0x0007. During execution of the Program
Once command, any attempt to read addresses within P-Flash block 0 will return invalid data.
24.4.2.7
The Erase All Blocks operation will erase the entire P-Flash and D-Flash memory space including the EEE
nonvolatile information register.
874
1. If a Program Once phrase is initially programmed to 0xFFFF_FFFF_FFFF_FFFF, the Program Once command will
be allowed to execute again on that same phrase.
FERSTAT
Register
FSTAT
Erase All Blocks Command
CCOBIX[2:0]
MGSTAT1
MGSTAT0
EPVIOLIF
ACCERR
Table 24-43. Program Once Command FCCOB Requirements
Error Bit
FPVIOL
000
001
010
011
100
101
Table 24-44. Program Once Command Error Handling
MC9S12XE-Family Reference Manual , Rev. 1.23
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Set if an invalid phrase index is supplied
Set if the requested phrase has already been programmed
None
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
None
Program Once phrase index (0x0000 - 0x0007)
0x07
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
FCCOB Parameters
Error Condition
Not Required
Table
24-30)
(1)