PEF82912FV14XP Lantiq, PEF82912FV14XP Datasheet - Page 128

PEF82912FV14XP

Manufacturer Part Number
PEF82912FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF82912FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Supplier Unconfirmed
Command
Activation Indication
Loop
Deactivation
Confirmation
Indication
Timing
Receiver not
Synchronous
Activation Request
Illegal Code Ciolation
Activation Indication
Deactivation
Indication
Data Sheet
Abbr.
AIL
DC
Abbr.
TIM
RSY
AR
CVR
AI
DI
Code
1110
1111
1000
1011
Code
0000
0100
1100
1111
114
Remark
Activation Indication Loop
Deactivation Confirmation. Transfers the
transceiver into a deactivated state in which
it can be activated from a terminal (detection
of INFO 0 enabled).
Remark
Interim indication during deactivation
procedure.
Receiver is not synchronous.
INFO 0 received from terminal. Activation
proceeds.
Illegal code violation received. This function
has to be enabled in S_CONF0.EN_ICV.
Synchronous receiver, i.e. activation
completed.
Timer (32 ms) expired or INFO 0 received for
a duration of 16 ms after deactivation
request.
Functional Description
PEF 82912/82913
2001-03-30