ISP1362BD NXP Semiconductors, ISP1362BD Datasheet - Page 89

no-image

ISP1362BD

Manufacturer Part Number
ISP1362BD
Description
USB Interface IC USB OTG CONTROLLER
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1362BD

Operating Supply Voltage
3 V to 3.6 V
Lead Free Status / Rohs Status
 Details
Other names
ISP1362BD,157

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1362BD
Manufacturer:
NXP
Quantity:
672
Part Number:
ISP1362BD
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
ISP1362BD
Quantity:
191
Part Number:
ISP1362BDFA
Manufacturer:
STE
Quantity:
5
Part Number:
ISP1362BDFA
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1362BDTM
Manufacturer:
NANYA
Quantity:
1 001
Part Number:
ISP1362BDTM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
NXP Semiconductors
Table 63.
ISP1362_5
Product data sheet
Bit
Symbol
Reset
Access
Bit
Symbol
Reset
Access
HcHardwareConfiguration register: bit allocation
14.4.1 HcHardwareConfiguration register (R/W: 20h/A0h)
Suspend_
OneDMA
Wakeup
14.4 HC DMA and interrupt control registers
Disable
R/W
R/W
15
0
7
0
Table 62.
The bit allocation of the HcHardwareConfiguration register is given in
Code (Hex): 20 — read
Code (Hex): A0 — write
Bit
1
0
DACKInput
Polarity
Global
Power
Down
R/W
R/W
14
0
6
0
HcRhPortStatus[1:2] register: bit description
Symbol
PES
CCS
PullDown
Connect
Polarity
Output
DREQ
_DS2
R/W
R/W
13
0
5
1
Rev. 05 — 8 May 2007
Description
On read PortEnableStatus: This bit indicates whether the port is
enabled or disabled. The root hub may clear this bit when an
overcurrent condition, disconnect event, switched-off power or
operational bus error, such as babble, is detected. This change also
causes PortEnableStatusChange to be set. The HCD sets this bit by
writing SetPortEnable and clears it by writing ClearPortEnable. This bit
cannot be set when CurrentConnectStatus (CCS) is cleared. This bit
is also set, if it is not already, at the completion of a port reset when
PortResetStatusChange is set or port suspend when
PortSuspendStatusChange is set.
0 — port is disabled
1 — port is enabled
On write SetPortEnable: The HCD sets PortEnableStatus (PES) by
writing logic 1. Writing logic 0 has no effect. If CurrentConnectStatus
(CCS) is cleared, this write does not set PortEnableStatus (PES), but
instead sets ConnectStatusChange (CSC). This informs the driver that
it attempted to enable a disconnected port.
On read CurrentConnectStatus: This bit reflects the current state of
the downstream port.
0 — no device connected
1 — device connected
On write ClearPortEnable: The HCD writes logic 1 to this bit to clear
the PortEnableStatus (PES) bit. Writing logic 0 has no effect.
CurrentConnectStatus (CSC) is not affected by any write.
Remark: This bit always reads logic 1 when the attached device is
nonremovable (DeviceRemovable[NDP]).
PullDown
Connect
_DS1
DataBusWidth[1:0]
R/W
R/W
12
0
4
0
ClkNotStop
Suspend
R/W
R/W
11
0
3
1
AnalogOC
Interrupt
…continued
Polarity
Single-chip USB OTG Controller
Enable
Output
R/W
R/W
10
0
2
0
PinTrigger
Interrupt
OneINT
R/W
R/W
Table
9
0
1
0
© NXP B.V. 2007. All rights reserved.
ISP1362
63.
InterruptPin
Enable
DACK
Mode
R/W
R/W
88 of 152
8
0
0
0

Related parts for ISP1362BD