AT32UC3A3128 Atmel Corporation, AT32UC3A3128 Datasheet - Page 81

no-image

AT32UC3A3128

Manufacturer Part Number
AT32UC3A3128
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A3128

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
110
Ext Interrupts
110
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Lin
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
12
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A3128-ALUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A3128-ALUT
Manufacturer:
Atmel
Quantity:
135
Part Number:
AT32UC3A3128-ALUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A3128-CTUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A3128-CTUT
Manufacturer:
Atmel
Quantity:
1 801
Part Number:
AT32UC3A3128-CTUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A3128-CTUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3A3128-U
Manufacturer:
ATMEL
Quantity:
11
10.2.5
10.2.6
32072G–11/2011
PDCA
HMATRIX
Power Manager
AES
Fix/Workaround
Disable mode fault detection by writing a one to MR.MODFDIS.
Disabling SPI has no effect on the SR.TDRE bit
Disabling SPI has no effect on the SR.TDRE bit whereas the write data command is filtered
when SPI is disabled. Writing to TDR when SPI is disabled will not clear SR.TDRE. If SPI is
disabled during a PDCA transfer, the PDCA will continue to write data to TDR until its buffer
is empty, and this data will be lost.
Fix/Workaround
Disable the PDCA, add two NOPs, and disable the SPI. To continue the transfer, enable the
SPI and PDCA.
Clock sources will not be stopped in STATIC sleep mode if the difference between
CPU and PBx division factor is too high
If the division factor between the CPU/HSB and PBx frequencies is more than 4 when going
to a sleep mode where the system RC oscillator is turned off, then high speed clock sources
will not be turned off. This will result in a significantly higher power consumption during the
sleep mode.
Fix/Workaround
Before going to sleep modes where the system RC oscillator is stopped, make sure that the
factor between the CPU/HSB and PBx frequencies is less than or equal to 4.
PCONTROL.CHxRES is non-functional
PCONTROL.CHxRES is non-functional. Counters are reset at power-on, and cannot be
reset by software.
Fix/Workaround
Software needs to keep history of performance counters.
Transfer error will stall a transmit peripheral handshake interface
If a transfer error is encountered on a channel transmitting to a peripheral, the peripheral
handshake of the active channel will stall and the PDCA will not do any more transfers on
the affected peripheral handshake interface.
Fix/Workaround
Disable and then enable the peripheral after the transfer error.
URAD (Unspecified Register Access Detection Status) does not detect read accesses
to the write-only KEYW[5..8]R registers
Fix/Workaround
None.
In the PRAS and PRBS registers, the MxPR fields are only two bits
In the PRAS and PRBS registers, the MxPR fields are only two bits wide, instead of four bits.
The unused bits are undefined when reading the registers.
Fix/Workaround
Mask undefined bits when reading PRAS and PRBS.
81