AT32UC3A464S Atmel Corporation, AT32UC3A464S Datasheet - Page 640

no-image

AT32UC3A464S

Manufacturer Part Number
AT32UC3A464S
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A464S

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
AES
Sram (kbytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A464S-U
Manufacturer:
ATMEL
Quantity:
551
26.7.2.13
32072G–11/2011
Management of OUT endpoints
•Overview
Figure 26-18. Abort Algorithm
OUT packets are sent by the host. All the data can be read which acknowledges or not the bank
when it is empty.
The endpoint must be configured first.
The RXOUTI bit is set at the same time as FIFOCON when the current bank is full. This triggers
an EPnINT interrupt if the Received OUT Data Interrupt Enable (RXOUTE) bit in UECONn is
one.
RXOUTI shall be cleared by software (by writing a one to the Received OUT Data Interrupt Clear
(RXOUTIC) bit) to acknowledge the interrupt, what has no effect on the endpoint FIFO.
The user then reads from the FIFO (see
DATA)” on page
composed of multiple banks, this also switches to the next bank. The RXOUTI and FIFOCON
bits are updated in accordance with the status of the next bank.
RXOUTI shall always be cleared before clearing FIFOCON.
The RWALL bit is set when the current bank is not empty, i.e. the software can read further data
from the FIFO.
TXINEC = 1
EPRSTn = 1
Abort Done
NBUSYBK
Endpoint
Abort
740) and clears the FIFOCON bit to free the bank. If the OUT endpoint is
== 0?
Yes
No
Yes
KILLBKS = 1
KILLBK
No
”USB Pipe/Endpoint n FIFO Data Register (USBFIFOn-
== 1?
Disable the TXINI interrupt.
Abort is based on the fact
that no bank is busy, i.e.,
that nothing has to be sent
Wait for the end of the
procedure
Kill the last written bank.
640