AT32UC3A464S Atmel Corporation, AT32UC3A464S Datasheet - Page 987

no-image

AT32UC3A464S

Manufacturer Part Number
AT32UC3A464S
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A464S

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
AES
Sram (kbytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A464S-U
Manufacturer:
ATMEL
Quantity:
551
38. Errata
38.1
38.1.1
38.1.2
38.1.3
32072G–11/2011
Rev. H
General
Processor and Architecture
USB
MPU
DMACA
CTLx.DST_TR_WIDTH
Fix/Workaround
For any DMACA transfer make sure CTLx.SRC_TR_WIDTH = CTLx.DST_TR_WIDTH.
LDM instruction with PC in the register list and without ++ increments Rp
For LDM with PC in the register list: the instruction behaves as if the ++ field is always set, ie
the pointer is always updated. This happens even if the ++ field is cleared. Specifically, the
increment of the pointer is done in parallel with the testing of R12.
Fix/Workaround
None.
Hardware breakpoints may corrupt MAC results
Hardware breakpoints on MAC instructions may corrupt the destination register of the MAC
instruction.
Fix/Workaround
Place breakpoints on earlier or later instructions.
When the main clock is RCSYS, TIMER_CLOCK5 is equal to PBA clock
When the main clock is generated from RCSYS, TIMER_CLOCK5 is equal to PBA Clock
and not PBA Clock / 128.
Fix/Workaround
None.
Privilege violation when using interrupts in application mode with protected system
stack
If the system stack is protected by the MPU and an interrupt occurs in application mode, an
MPU DTLB exception will occur.
Fix/Workaround
Make a DTLB Protection (Write) exception handler which permits the interrupt request to be
handled in privileged mode.
As a consequence, isochronous IN and OUT tokens are sent every 1ms (Full Speed), or
every 125uS (High Speed).
Fix/Workaround
For higher polling time, the software must freeze the pipe for the desired period in order to
prevent any "extra" token.
UPCFGn.INTFRQ is irrelevant for isochronous pipe
data
transfer
fails
when
CTLx.SRC_TR_WIDTH
is
not
equal
987
to

Related parts for AT32UC3A464S