HD64F3672FPIV Renesas Electronics America, HD64F3672FPIV Datasheet - Page 216

MCU 3/5V 16K I-TEMP PB-FREE 64-L

HD64F3672FPIV

Manufacturer Part Number
HD64F3672FPIV
Description
MCU 3/5V 16K I-TEMP PB-FREE 64-L
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3672FPIV

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
26
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
For Use With
R0K436079S000BE - KIT DEV FOR H8/36079 W/COMPILER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Section 13 Serial Communication Interface 3 (SCI3)
Rev.4.00 Nov. 02, 2005 Page 190 of 304
REJ09B0143-0400
[4]
Figure 13.13 Sample Serial Reception Flowchart (Clocked Synchronous Mode)
Yes
No
Read receive data in RDR
Clear OER flag in SSR to 0
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Overrun error processing
Read OER flag in SSR
All data received?
Error processing
Start reception
RDRF = 1
OER = 1
<End>
<End>
Yes
No
No
(Continued below)
Error processing
Yes
[1]
[2]
[3]
[4]
[1]
[2]
[3]
[4]
Read the OER flag in SSR to determine if
there is an error. If an overrun error has
occurred, execute overrun error processing.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR.
When data is read from RDR, the RDRF
flag is automatically cleared to 0.
To continue serial reception, before the
MSB (bit 7) of the current frame is received,
reading the RDRF flag and reading RDR
should be finished. When data is read from
RDR, the RDRF flag is automatically
cleared to 0.
If an overrun error occurs, read the OER
flag in SSR, and after performing the
appropriate error processing, clear the OER
flag to 0. Reception cannot be resumed if
the OER flag is set to 1.

Related parts for HD64F3672FPIV