HD6413008VX25 Renesas Electronics America, HD6413008VX25 Datasheet - Page 111

MCU 5V 0K 100-TQFP

HD6413008VX25

Manufacturer Part Number
HD6413008VX25
Description
MCU 5V 0K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413008VX25

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
PWM, WDT
Number Of I /o
35
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6413008VTE25
HD6413008VTE25
4.1
4.1.1
As table 4.1 indicates, exception handling may be caused by a reset, interrupt, or trap instruction.
Exception handling is prioritized as shown in table 4.1. If two or more exceptions occur
simultaneously, they are accepted and processed in priority order. Trap instruction exceptions are
accepted at all times in the program execution state.
Table 4.1
Priority Exception Type
High
Low
4.1.2
Exceptions originate from various sources. Trap instructions and interrupts are handled as follows.
1. The program counter (PC) and condition code register (CCR) are pushed onto the stack.
2. The CCR interrupt mask bit is set to 1.
3. A vector address corresponding to the exception source is generated, and program execution
Note: For a reset exception, steps 2 and 3 above are carried out.
starts from that address.
Reset
Interrupt
Trap instruction (TRAPA) Started by execution of a trap instruction (TRAPA)
Overview
Exception Handling Types and Priority
Exception Handling Operation
Exception Types and Priority
Section 4 Exception Handling
Start of Exception Handling
Starts immediately after a low-to-high transition at the RES pin
Interrupt requests are handled when execution of the current
instruction or handling of the current exception is completed
Rev.4.00 Aug. 20, 2007 Page 65 of 638
4. Exception Handling
REJ09B0395-0400

Related parts for HD6413008VX25