MC68HC908GP32CP Freescale Semiconductor, MC68HC908GP32CP Datasheet - Page 365

IC MCU 8MHZ 32K FLASH 40-DIP

MC68HC908GP32CP

Manufacturer Part Number
MC68HC908GP32CP
Description
IC MCU 8MHZ 32K FLASH 40-DIP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908GP32CP

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
33
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
40-DIP (0.600", 15.24mm)
For Use With
M68EVB908GP32 - BOARD EVALUATION FOR HC908GP32
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908GP32CP
Manufacturer:
ROCKWELL
Quantity:
201
Part Number:
MC68HC908GP32CP
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
22.10.5 TIM Channel Registers
MC68HC908GP32
MOTOROLA
NOTE:
NOTE:
MC68HC08GP32
Before enabling a TIM channel register for input capture operation, make
sure that the PTDx/TCHx pin is stable for at least two bus clocks.
TOVx — Toggle On Overflow Bit
When TOVx is set, a TIM counter overflow takes precedence over a
channel x output compare if both occur at the same time.
CHxMAX — Channel x Maximum Duty Cycle Bit
These read/write registers contain the captured TIM counter value of the
input capture function or the output compare value of the output
compare function. The state of the TIM channel registers after reset is
unknown.
CHxMAX
When channel x is an output compare channel, this read/write bit
controls the behavior of the channel x output when the TIM counter
overflows. When channel x is an input capture channel, TOVx has no
effect.
Reset clears the TOVx bit.
When the TOVx bit is at logic 1, setting the CHxMAX bit forces the
duty cycle of buffered and unbuffered PWM signals to 100%. As
Figure 22-11
is set or cleared. The output stays at the 100% duty cycle level until
the cycle after CHxMAX is cleared.
TCHx
1 = Channel x pin toggles on TIM counter overflow
0 = Channel x pin does not toggle on TIM counter overflow
OVERFLOW
Rev. 6
Timer Interface Module (TIM)
COMPARE
PERIOD
OUTPUT
shows, the CHxMAX bit takes effect in the cycle after it
Figure 22-11. CHxMAX Latency
OVERFLOW
COMPARE
OUTPUT
OVERFLOW
COMPARE
OUTPUT
Timer Interface Module (TIM)
OVERFLOW
COMPARE
OUTPUT
Technical Data
OVERFLOW
I/O Registers
363

Related parts for MC68HC908GP32CP