AD7711ANZ Analog Devices Inc, AD7711ANZ Datasheet - Page 9

no-image

AD7711ANZ

Manufacturer Part Number
AD7711ANZ
Description
24 BIT SIGMA DELTA ADC IC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7711ANZ

Rohs Compliant
YES
Number Of Bits
24
Sampling Rate (per Second)
1.03k
Data Interface
Serial
Number Of Converters
1
Power Dissipation (max)
45mW
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 80°C
Mounting Type
Through Hole
Package / Case
24-DIP (0.300", 7.62mm)
Resolution (bits)
24bit
Sampling Rate
19.5kSPS
Input Channel Type
Differential, Single Ended
Supply Voltage Range - Analogue
5V To 10V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7711ANZ
Manufacturer:
AD
Quantity:
1
CONTROL REGISTER (24 BITS)
A write to the device with the A0 input low writes data to the control register. A read to the device with the A0 input low accesses the
contents of the control register. The control register is 24 bits wide; 24 bits of data must be written to the registers or the data will not
be loaded. In other words, it is not possible to write just the first 12-bits of data into the control register. If more than 24 clock pulses
are provided before TFS returns high, then all clock pulses after the 24th clock pulse are ignored. Similarly, a read operation from the
control register should access 24 bits of data.
MD2
0
0
0
0
1
1
1
1
REV.G
Operating Mode
MD1
0
0
1
1
0
0
1
1
MD0
0
1
0
1
0
1
0
1
MSB
MD2
FS11
Operating Mode
Normal Mode. This is the normal mode of operation where a read to the device with A0 high accesses
data from the data register. This is the default condition of these bits after the internal power-on reset.
Activate Self-Calibration. This activates self-calibration on the channel selected by CH. This is a one-step
calibration sequence, and when complete, the part returns to normal mode (with MD2, MD1, MD0 of
the control register returning to 0, 0, 0). The DRDY output indicates when this self-calibration is complete.
For this calibration type, the zero-scale calibration is done internally on shorted (zeroed) inputs, and the
full-scale calibration is done internally on V
Activate System Calibration. This activates system calibration on the channel selected by CH. This is a
two-step calibration sequence, with the zero-scale calibration done first on the selected input channel and
DRDY indicating when this zero-scale calibration is complete. The part returns to normal mode at the
end of this first step in the two-step sequence.
Activate System Calibration. This is the second step of the system calibration sequence with full-scale
calibration being performed on the selected input channel. Once again, DRDY indicates when the full-
scale calibration is complete. When this calibration is complete, the part returns to normal mode.
Activate System Offset Calibration. This activates system offset calibration on the channel selected by
CH. This is a one-step calibration sequence and, when complete, the part returns to normal mode with
DRDY indicating when this system offset calibration is complete. For this calibration type, the zero-scale
calibration is done on the selected input channel, and the full-scale calibration is done internally on V
Activate Background Calibration. This activates background calibration on the channel selected by CH. If
the background calibration mode is on, the AD7711 provides continuous self-calibration of the
reference and shorted (zeroed) inputs. This calibration takes place as part of the conversion sequence,
extending the conversion time and reducing the word rate by a factor of 6. The major advantage is that
the user does not have to recalibrate the device when there is a change in the ambient temperature. In this
mode, the shorted (zeroed) inputs and V
tored and the calibration registers of the device are automatically updated.
Read/Write Zero-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents
of the zero-scale calibration coefficients of the channel selected by CH. A write to the device with A0 high
writes data to the zero-scale calibration coefficients of the channel selected by CH. The word length for
reading and writing these coefficients is 24 bits, regardless of the status of the WL bit of the control
register. Therefore, 24 bits of data must be written to the calibration register or the new data will not be
transferred to the calibration register.
Read/Write Full-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents of
the full-scale calibration coefficients of the channel selected by CH. A write to the device with A0 high
writes data to the full-scale calibration coefficients of the channel selected by CH. The word length for
reading and writing these coefficients is 24 bits, regardless of the status of the WL bit of the control
register. Therefore, 24 bits of data must be written to the calibration register, or the new data will not be
transferred to the calibration register.
MD1
FS10
MD0
FS9
G2
FS8
G1
FS7
G0
FS6
–9–
REF
CH
FS5
REF
, as well as the analog input voltage, are continuously moni-
.
PD
FS4
WL
FS3
RO
FS2
BO
FS1
B/U
FS0
LSB
AD7711
REF
.
2