CS1W-CN625 Omron, CS1W-CN625 Datasheet - Page 42

no-image

CS1W-CN625

Manufacturer Part Number
CS1W-CN625
Description
CBL,PROG
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN625

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1-5
1-5-2
1-24
CPU Unit built-in
serial port
Serial port on
Inner Board
(Nothing
displayed if an
Inner Board is not
mounted.)
Communications
Unit name, Model
Description:
Communications
Unit/port
Window Descriptions
Main Window
Communications Unit and Port Information for Target PLC
CPU Unit/port
Serial Communications
Board
Communications Unit
name (Ethernet Unit,
Controller Link Unit,
SYSMAC LINK Unit, or
DeviceNet Unit)
The following CPU Unit built-in serial ports, Inner Boards, and Communications Units
(referred to here as Communications Units/Ports) that are part of the target PLC are
displayed under TargetPLC in directory tree format.
If a connection is established and access is enabled for a Communications Unit/port,
the icon on the left will be
Right-click the Communications Unit/port and select Connect to connect to the
Communications Unit/port and enable access. (With the CX-Integrator, only one
Communications Unit/port can be accessed at any one time.)
The actual network configuration can then be uploaded by right-clicking the
Communications Unit/port and selecting Transfer − Network to PC.
Display format:
Right of
Unit name
or
FINS unit address)
or
: Not connected (access not possible).
: Connected (access possible).
:
Target PLC’s
CPU Unit
model
Serial
Communicatio
ns Board
model
Communicatio
ns Unit model
Unit name [Unit model] Net (network address) Node (node address) Unit (unit number or
[Unit model]
instead of
The network address
(1 to 127, decimal),
when the serial port is
registered in the local
network table to treat
it as a network.
Note: “−” will be
displayed if the serial
port is not registered
in the local network
table.
Same as above.
Network address (1 to
127, decimal)
Note: “−” will be
displayed if a local
network table is not
registered.
Net (Network
address)
.
− (Does not
change.)
− (Does not
change.)
Node
address
(node ID on
the network)
Node (Node
address)
Serial port’s FINS
unit address
(decimal)
Peripheral port: 253
RS-232C port: 252
Note: “−” will be
displayed if the
serial port is not
registered in the
local network table.
Serial port’s FINS
unit address
(decimal)
Port 1: 255
Port 2: 226
Note: “−” will be
displayed if the
serial port is not
registered in the
local network table.
Unit number
(decimal)
(Rotary switch on
front of CPU Bus
Unit: 0 to 15)
Unit (Unit number
or FINS unit
address)

Related parts for CS1W-CN625