CS1W-CRM21 Omron, CS1W-CRM21 Datasheet - Page 64

no-image

CS1W-CRM21

Manufacturer Part Number
CS1W-CRM21
Description
CS1 CompoNet Master
Manufacturer
Omron
Datasheet

Specifications of CS1W-CRM21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1-5
1-5-2
1-36
CPU Unit built-in
serial port
Serial port on
Inner Board
(Nothing
displayed if an
Inner Board is not
mounted.)
Communications
Unit name, Model
Description:
Communications
Unit/port
Window Descriptions
Main Window
Connection status
CPU port [CJ1M-CPU22] Net (−) Node (2) Unit (0)
: Connected (access possible)
: Not connected (access not possible)
CPU Unit/port
Serial Communications
Board
Communications Unit
name (Ethernet Unit,
Controller Link Unit,
SYSMAC LINK Unit, or
DeviceNet Unit)
CompoNet Master Unit
name
Communications Unit and Port Information for Target PLC
The following CPU Unit built-in serial ports, Inner Boards, and Communications Units
(referred to here as Communications Units/Ports) that are part of the target PLC are
displayed under TargetPLC in directory tree format.
If a connection is established and access is enabled for a Communications Unit/port,
the icon on the left will be
Right-click the Communications Unit/port and select Connect to connect to the
Communications Unit/port and enable access. (With the CX-Integrator, only one
Communications Unit/port can be accessed at any one time.)
The actual network configuration can then be uploaded by right-clicking the
Communications Unit/port and selecting Transfer
1) Right of
Unit name
or
:
Target PLC’s
CPU Unit
model
Serial Com-
munications
Board model
Communicatio
ns Unit model
2) Unit model
instead of
The network address
(1 to 127, decimal),
when the serial port is
registered in the local
network table to treat
it as a network.
Note: “−” will be
Same as above.
Network address (1 to
127, decimal)
Note: “−” will be
displayed if a local
network table is not
registered.
− (Does not change.)
3) Network address
displayed if the
serial port is not
registered in the
local network
table.
.
Network to PC.
1) Unit name
5) Unit number of FINS unit address
4) Node address
3) Network address
2) Unit model
− (Does not
change.)
− (Does not
change.)
Node
address
(node ID on
the network)
− (Does not
change.)
address
4) Node
Serial port’s FINS
unit address
(decimal)
Peripheral port: 253
RS-232C port: 252
Note: “−” will be
Serial port’s FINS
unit address
(decimal)
Port 1: 225
Port 2: 226
Note: “−” will be
Unit number
(decimal)
(Rotary switch on
front of CPU Bus
Unit: 0 to 15)
Unit number
(decimal)
(Master Unit rotary
switch number: 0 to
99)
FINS unit address
5) Unit number or
displayed if
the serial port
is not
registered in
the local
network
table.
displayed if
the serial port
is not
registered in
the local
network
table.