DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 229

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 6: BERT Bit-Error Detected (BED) Event (BBED). A latched bit that is set when a bit error is detected. The
receive BERT must be in synchronization for it to detect bit errors. Cleared when read.
Bit 5: BERT Bit-Counter Overflow Event (BBCO). A latched bit that is set when the 32-bit BERT bit counter
(BBC) overflows. Cleared when read and is not set again until another overflow occurs.
Bit 4: BERT Error-Counter Overflow (BECO) Event (BECO). A latched bit that is set when the 24-bit BERT error
counter (BEC) overflows. Cleared when read and is not set again until another overflow occurs.
Bit 3: BERT Receive All-Ones Condition (BRA1). A latched bit that is set when 32 consecutive 1s are received.
Allowed to be cleared once a 0 is received. This is a double interrupt bit (Section 9.7).
Bit 2: BERT Receive All-Zeros Condition (BRA0). A latched bit that is set when 32 consecutive 0s are received.
Allowed to be cleared once a 1 is received. This is a double interrupt bit (Section 9.7).
Bit 1: BERT Receive Loss-of-Synchronization Condition (BRLOS). A latched bit that is set whenever the
receive BERT begins searching for a pattern. Once synchronization is achieved, this bit remains set until read. This
is a double interrupt bit (Section 9.7).
Bit 0: BERT in Synchronization Condition (BSYNC). Set when the incoming pattern matches for 32 consecutive
bit positions. Refer to BSYNC in the TR.INFO2 register for a real-time version of this bit. This is a double interrupt
bit (Section 9.7).
7
0
TR.SR9
Status Register 9
26h
BBED
6
0
BBCO
5
0
229 of 344
BEC0
0
4
BRA1
3
0
BRA0
2
0
BRLOS
1
0
BSYNC
0
0

Related parts for DS33R11