DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 239

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 6: Manual Error-Counter Update (MECU). When enabled by TR.ERCNT.4, the changing of this bit from a 0 to
a 1 allows the next clock cycle to load the error-counter registers with the latest counts and reset the counters. The
user must wait a minimum of 1.5 RCLKO clock periods before reading the error count registers to allow for proper
update.
Bit 5: Error-Counter Update Select (ECUS)
Bit 4: Error-Accumulation Mode Select (EAMS)
Bit 3: E1 Line-Code Violation Count Register Function Select (VCRFS)
Bit 2: PCVCR Fs-Bit Error-Report Enable (FSBE)
Bit 1: Multiframe Out-of-Sync Count Register Function Select (MOSCRF)
Bit 0: T1 Line-Code Violation Count Register Function Select (LCVCRF)
T1 Mode:
E1 Mode:
0 = update error counters once a second
1 = update error counters every 42ms (333 frames)
0 = update error counters once a second
1 = update error counters every 62.5ms (500 frames)
0 = TR.ERCNT.5 determines accumulation time
1 = TR.ERCNT.6 determines accumulation time
0 = count bipolar violations (BPVs)
1 = count code violations (CVs)
0 = do not report bit errors in Fs-bit position; only Ft-bit position
1 = report bit errors in Fs-bit position as well as Ft-bit position
0 = count errors in the framing bit position
1 = count the number of multiframes out-of-sync
0 = do not count excessive 0s
1 = count excessive 0s
7
0
TR.ERCNT
Error-Counter Configuration Register
41h
MECU
6
0
ECUS
5
0
239 of 344
EAMS
0
4
VCRFS
3
0
FSBE
2
0
MOSCRF
1
0
LCVCRF
0
0

Related parts for DS33R11