RC82562EP Intel, RC82562EP Datasheet - Page 118

no-image

RC82562EP

Manufacturer Part Number
RC82562EP
Description
IC ETH 10/100 PLC DEV CTRL 64BGA
Manufacturer
Intel
Datasheets

Specifications of RC82562EP

Rohs Status
RoHS non-compliant
Controller Type
Ethernet Controller
Interface
IEEE 802.3
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
64-BGA
Current - Supply
-
Operating Temperature
-
Other names
832361

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RC82562EP
Manufacturer:
Intel
Quantity:
10 000
Host Software Interface
6.6.2.2
6.6.2.3
110
Note: The 82557 does not support flow control functionality.
Intel 8255x 10/100 Mbps Ethernet Controller Family Open Source Software Developer Manual
A flow control frame is identified by a special type field (bytes transmitted left to right): 88 to 80.
The reception of a FC frame can be done either through the regular individual address filtering
mechanism or by a special multicast address detection mechanism. Since the transmitting MAC
may not know the individual address of the other station, it may not be able to send FC frames to
the individual address of the other node. A special multicast destination address is defined for use
in FC frames. Special address filtering is used to receive frames addressed to that multicast
address. The address is (bytes transmitted left to right): 01-80-C2-00-00-01.
Pause Operation
When a station’s receive buffer reaches a high watermark (running out of storage space for
incoming packets), it may send its link partner a pause frame (also known as an XOFF frame).
When the station receives the pause request, it stops transmitting for a number of slot times as
specified by the time parameter in the pause frame. The time parameter is a 2 byte field.
The reaction time for a transmitting station (the congester) is 512 bit times from the end of the
received pause frame. If the congester is transmitting when the time expires, it should complete the
transmitted frame. The congester should not start transmitting a frame after the 512-bit time period.
Transmission is restarted upon expiration of the pause timer or upon reception of a pause request
with a time parameter of zero (also known as an XON frame).
Flow Control Functionality
Table 54. Flow Control Frame Format
Source Address
MAC Control
MAC Control
Type/Length
Destination
Parameters
Pre-amble
Address
Opcode
SFD
FCS
S
T
one byte
up to 6 bytes
one byte
6 bytes
6 bytes
2 bytes
2 bytes
4 bytes
one byte

Related parts for RC82562EP