FQM1-TER01 Omron, FQM1-TER01 Datasheet - Page 241

no-image

FQM1-TER01

Manufacturer Part Number
FQM1-TER01
Description
5M 4COND 22AWG TPE ST MALE M12
Manufacturer
Omron
Datasheet

Specifications of FQM1-TER01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
FQM1TER01
Pulse Inputs
Latching a High-speed
Counter’s PV
214
Note
This function monitors the input pulse’s frequency from the high-speed
counter movement value. The frequency is stored in A854 and A855. Status
Flag A858.06 can be checked to determine whether or not the frequency is
being measured.
The pulse input’s counter data display must be set to frequency measurement
(mode 2) in the System Setup in advance.
Frequency Measurement (Mode 2) Specifications
The present counter value can be latched at the rising edge of the latch signal
input and stored as the latch register value. Each time the counter value is
captured, the latch register value is overwritten with the new value and the old
value is lost.
A854 and
A855
A858
Pulse Input Tab
Page
Counter data display
Applicable pulse
input
Measurable frequen-
cies
Measurement period 5 ms max. (input frequency 500 Hz min.)
Operating conditions In the System Setup, set the pulse input’s counter data display
(1) The frequency value stored in the Auxiliary Area is refreshed during the
(2) The frequency measurement can be performed only with high-speed
(3) When measurement is started, the measurement direction (A860.03)
Word
System Setup
Motion Control Module’s I/O refreshing.
counter 1. The frequency cannot be measured with high-speed counter 2.
must be specified to match the direction of the input pulses being mea-
sured.
Item
00 to 15
06
Bits
Specifies the counter 1 mea-
surement mode.
Only pulse 1 (high-speed counter 1) can be used.
0 to 500 kHz
Note When no pulses have been input for 10 s, the measured
Note At input frequencies below 500 Hz, the measurement
to frequency measurement (mode 2).
High-speed Counter 1
Monitor Data
High-speed Counter 1
Status Flag
value is set to 0 Hz (stopped). The previous output
value is retained during this 10-second interval.
period is increased to accommodate the lower input fre-
quencies and becomes 200 ms max. for input frequen-
cies of 10 Hz min.
Function
Function
Specifications
Contains the frequency measure-
ment.
The frequency calculated from the
high-speed counter PV is stored in
8-digit hexadecimal (0000 0000 to
0007 A120 hex = 0 to 500 kHz).
Measuring Flag
OFF: The high-speed counter fre-
ON:
quency measurement opera-
tion is stopped.
quency is being measured.
The high-speed counter fre-
2 hex: Frequency (mode 2)
Details
Details
Section 7-5