FQM1-TER01 Omron, FQM1-TER01 Datasheet - Page 32

no-image

FQM1-TER01

Manufacturer Part Number
FQM1-TER01
Description
5M 4COND 22AWG TPE ST MALE M12
Manufacturer
Omron
Datasheet

Specifications of FQM1-TER01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
FQM1TER01
High-speed Analog I/O
Supported
Writing and Monitoring
Ladder Programs
1-2
FQM1-CM002 Coordinator
Module
FQM1 Configuration
FQM1 Configuration
Power Supply Unit
CX-Programmer
Peripheral port
Note
Coordinator Module
RS-232C port
Motion Control Modules with analog I/O support linear (displacement/length
measurement) sensor input, inverter control, and control of Servomotors with
analog-input Servo Drivers. This gives flexibility for a great variety of motion
applications.
The ladder program for each Module is written using the CX-Programmer and
then written to each Module via the peripheral port on the Coordinator Mod-
ule.The ladder program is saved in each Module and operation of the program
can be monitored from the CX-Programmer.
The FQM1 consists of a Power Supply Unit, a Coordinator Module, one or
more Motion Control Modules, and an End Module. Motion Control Modules
are available with either pulse I/O or analog I/O and up to four Motion Control
Modules can be connected in one system. (See note.)
The number of Motion Control Modules with Analog I/O that can be connected
is limited by the output capacity of the Power Supply Unit.
One Coordinator Module is required in an FQM1. The Coordinator Module
provides the following:
I/O:
Program capacity: 10 Ksteps
DM Area capacity: 32 Kwords (DM)
• The CX-Programmer (Ver. 6.11 or later) is connected to the peripheral
• The Coordinator Module has its own ladder program, which is used to
• The Coordinator Module has 24 general-purpose I/O (16 inputs and 8 out-
Servo Relay Units
port on the Coordinator Module, and a PT (Programmable Terminal) or
other device is connected to the RS-232C port.
coordinate Motion Control Module data.
puts).
Servomotors/
Servo Drivers
Motion Control Modules
16 inputs, 8 outputs
I/O Control Module
RS-422A
CJ-series Units
End Module
Use the CJ-series E
Cover included with
FQM1-IC101.
Section 1-2
5