PEB 20571 F V3.1 Infineon Technologies, PEB 20571 F V3.1 Datasheet - Page 74

no-image

PEB 20571 F V3.1

Manufacturer Part Number
PEB 20571 F V3.1
Description
IC LINE CARD CTRLR DSP TQFP-100
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB 20571 F V3.1

Function
PBX Controller with DSP
Interface
ISDN
Voltage - Supply
3.13 V ~ 3.47 V
Current - Supply
272.6mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LFQFP
Includes
Layer-1 Control, Signaling Control, Signal Processing, Voice Channel Handling
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Number Of Circuits
-
Other names
PEB20571FV3.1X
PEB20571FV31XP
SP000007539
LT-S Mode States
• G1 deactivated
• G2 pending activation
• G3 activated
• G2 lost framing
• G4 pending deactivation
• G4 wait for DR
• Test mode 1
• Test mode 2
Data Sheet
The line interface is not transmitting. There is no signal detected on the S interface,
and no activation command is received.
As a result of an INFO 1 detected on the S line or an AR command, the line interface
begins transmitting INFO 2 and waits for reception of INFO 3. The timer to supervise
reception of INFO 3 is to be implemented in software. In case of an ARL command,
loop 2 is closed.
Normal state where INFO 4 is transmitted to the S interface. The line interface
remains in this state as long as neither a deactivation nor a test mode is requested,
and the receiver does not loose synchronism. When receiver synchronism is lost,
INFO 2 is sent automatically. After reception of INFO 3, the transmitter continues
sending INFO 4.
This state is reached when the line interface has lost synchronism in the state G3
activated.
This state is triggered by a deactivation request DR. It is an unstable state: status DI
(state “G4 wait for DR”) is issued by the DELIC when either INFO 0 is received, or an
internal timer of 32 ms expires.
Final state after a deactivation request. The line interface remains in this state until a
response to DI (in other words DC) is issued.
Single alternating pulses are sent on the S interface (2 kHz repetition rate).
Continuous alternating pulses are sent on the S interface (96 kHz).
57