Datasheet

Specifications of AT90PWM81

Flash (kbytes)
8 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
20
Ext Interrupts
3
Usb Speed
No
Usb Interface
No
Spi
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
125
Analog Comparators
3
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
1
Output Compare Channels
8
Input Capture Channels
1
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90PWM81-16MF
Manufacturer:
Atmel
Quantity:
3 118
Part Number:
AT90PWM81-16MN
Manufacturer:
Atmel
Quantity:
2 446
Part Number:
AT90PWM81-16SF
Manufacturer:
Atmel
Quantity:
2 428
Part Number:
AT90PWM81-16SN
Manufacturer:
Atmel
Quantity:
1 500
28.3
310
Errata AT90PWM81 revC
AT90PWM81
5. Flash and EEPROM programming failure if CPU clock is switched
6. ADC AMPlifier measurement is unstable
7. ADC measurement reports abnormal values with PSC2-synchronized
8. Over-consumption in power down sleep mode.
If Clock switching is used in the Application, the memory programming is only possible when
the internal RC oscillator is selected as System clock.
If the Application requires a memory programming on a clock source different from the inter-
nal RC oscillator, do not switch to this clock source.
Work around:
- Use internal RC oscillator when programming Flash and EEPROM,
or
- Do not use clock switching.
When switching from a single-ended ADC channel to an Amplified channel, noise can
appear on ADC conversion.
Work around:
After switching from a single ended to an amplified channel, discard the first ADC
conversion.
When using ADC in synchronized mode, an unexpected extra Single ended conversion can
spuriously re-start.This can occur when the End of conversion and the Trigger event occur
at the same time.
Work around:
No workaround
In Power-down mode, an extra power consumption up to 500µA may occur.
Work around:
No workaround
Clock Switch disable
Crystal oscillator control with Clock Switch
BOD disable fuse
PSC output at Reset
Flash and EEPROM programming failure if CPU clock is switched
ADC AMPlifier measurement is unstable
ADC measurement reports abnormal values with PSC2-synchronized conversions
Over-consumption in power down sleep mode.
conversions