SAM7X128 Atmel Corporation, SAM7X128 Datasheet - Page 308

no-image

SAM7X128

Manufacturer Part Number
SAM7X128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X128

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
30.6.1.1
30.6.1.2
Table 30-2.
308
Source Clock
3 686 400
4 915 200
5 000 000
7 372 800
MHz
SAM7X512/256/128
Baud Rate in Asynchronous Mode
Baud Rate Calculation Example
Baud Rate Example (OVER = 0)
Expected Baud
If the external SCK clock is selected, the duration of the low and high levels of the signal pro-
vided on the SCK pin must be longer than a Master Clock (MCK) period. The frequency of the
signal provided on SCK must be at least 4.5 times lower than MCK.
Figure 30-3. Baud Rate Generator
If the USART is programmed to operate in asynchronous mode, the selected clock is first
divided by CD, which is field programmed in the Baud Rate Generator Register (US_BRGR).
The resulting clock is provided to the receiver as a sampling clock and then divided by 16 or 8,
depending on the programming of the OVER bit in US_MR.
If OVER is set to 1, the receiver sampling is 8 times higher than the baud rate clock. If OVER is
cleared, the sampling is performed at 16 times the baud rate clock.
The following formula performs the calculation of the Baud Rate.
This gives a maximum baud rate of MCK divided by 8, assuming that MCK is the highest possi-
ble clock and that OVER is programmed at 1.
Table 30-2
clock frequencies. This table also shows the actual resulting baud rate and the error.
SCK
38 400
38 400
38 400
38 400
Rate
Bit/s
Reserved
MCK/DIV
Baudrate
MCK
shows calculations of CD to obtain a baud rate at 38400 bauds for different source
USCLKS
=
0
1
2
3
Calculation Result
--------------------------------------------
(
8 2 Over
SelectedClock
(
12.00
6.00
8.00
8.14
16-bit Counter
)CD
CD
)
USCLKS = 3
CD
12
6
8
8
0
SYNC
CD
>1
1
0
Actual Baud Rate
1
0
38 400.00
38 400.00
39 062.50
38 400.00
Bit/s
OVER
Sampling
Divider
FIDI
6120I–ATARM–06-Apr-11
0
1
SYNC
0.00%
0.00%
1.70%
0.00%
Error
SCK
Baud Rate
Sampling
Clock
Clock

Related parts for SAM7X128