SAM7X128 Atmel Corporation, SAM7X128 Datasheet - Page 73

no-image

SAM7X128

Manufacturer Part Number
SAM7X128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X128

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
14. Real-time Timer (RTT)
14.1
14.2
Figure 14-1. Real-time Timer
14.3
6120I–ATARM–06-Apr-11
SLCK
RTT_MR
Overview
Block Diagram
Functional Description
RTTRST
reload
Divider
16-bit
RTT_MR
RTPRES
The Real-time Timer is built around a 32-bit counter and used to count elapsed seconds. It gen-
erates a periodic interrupt or/and triggers an alarm on a programmed value.
The Real-time Timer is used to count elapsed seconds. It is built around a 32-bit counter fed by
Slow Clock divided by a programmable 16-bit value. The value can be programmed in the field
RTPRES of the Real-time Mode Register (RTT_MR).
Programming RTPRES at 0x00008000 corresponds to feeding the real-time counter with a 1 Hz
signal (if the Slow Clock is 32.768 Hz). The 32-bit counter can count up to 2
sponding to more than 136 years, then roll over to 0.
The Real-time Timer can also be used as a free-running timer with a lower time-base. The best
accuracy is achieved by writing RTPRES to 3. Programming RTPRES to 1 or 2 is possible, but
may result in losing status events because the status register is cleared two Slow Clock cycles
after read. Thus if the RTT is configured to trigger an interrupt, the interrupt occurs during 2 Slow
Clock cycles after reading RTT_SR. To prevent several executions of the interrupt handler, the
interrupt must be disabled in the interrupt handler and re-enabled when the status register is
clear.
RTT_VR
RTT_AR
RTT_MR
RTTRST
0
1
Counter
CRTV
32-bit
ALMV
0
RTT_SR
RTT_SR
RTT_SR
=
read
reset
reset
set
set
RTTINC
ALMS
SAM7X512/256/128
RTTINCIEN
RTT_MR
RTT_MR
ALMIEN
rtt_alarm
32
seconds, corre-
rtt_int
73

Related parts for SAM7X128