SAM7X256 Atmel Corporation, SAM7X256 Datasheet - Page 528

no-image

SAM7X256

Manufacturer Part Number
SAM7X256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7X256

Flash (kbytes)
256 Kbytes
Pin Count
100
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
62
Ext Interrupts
62
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
1
Uart
3
Can
1
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
Figure 36-18. Consumer Handling
36.7.4
36.7.4.1
Figure 36-19. Mailbox Timestamp
528
MTIMESTAMP
MTIMESTAMP
(CAN_MCRx)
(CAN_MSRx)
(CAN_MSRx)
(CAN_TSTP)
CAN_MDHx)
TIMESTAMP
(CAN_MSRx)
(CAN_MDLx
(CAN_MSRy)
(CAN_MR)
CAN BUS
CAN_TIM
CAN BUS
MRDY
MTCR
TEOF
MMI
SAM7X512/256/128
CAN Controller Timing Modes
Timestamping Mode
Using the free running 16-bit internal timer, the CAN controller can be set in one of the two fol-
lowing timing modes:
Timestamping Mode is enabled by clearing the TTM bit in the CAN_MR register. Time Triggered
Mode is enabled by setting the TTM bit in the CAN_MR register.
Each mailbox has its own timestamp value. Each time a message is sent or received by a mail-
box, the 16-bit value MTIMESTAMP of the CAN_TIMESTP register is transferred to the LSB bits
of the CAN_MSRx register. The value read in the CAN_MSRx register corresponds to the inter-
nal timer value at the Start Of Frame or the End Of Frame of the message handled by the
mailbox.
Remote Frame
Timestamp 1
• Timestamping Mode: The value of the internal timer is captured at each Start Of Frame or
• Time Triggered Mode: The mailbox transfer operation is triggered when the internal timer
Timestamp 1
Message 1
each End Of Frame.
reaches the mailbox trigger.
Start of Frame
Message x
End of Frame
Message x
Remote Frame
Message 2
Message y
Timestamp 2
Timestamp 2
Message y
6120I–ATARM–06-Apr-11