SAM9X35 Atmel Corporation, SAM9X35 Datasheet - Page 1029

no-image

SAM9X35

Manufacturer Part Number
SAM9X35
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9X35

Flash (kbytes)
0 Kbytes
Pin Count
217
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
105
Ext Interrupts
105
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
3
Uart
7
Can
2
Lin
4
Ssc
1
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
No
Adc Channels
12
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
Yes
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
DDR/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No/Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
44.9.13
Name:
Address:
Access:
• TXRDY: Transmit Ready
0 = Data has been loaded in SSC_THR and is waiting to be loaded in the Transmit Shift Register (TSR).
1 = SSC_THR is empty.
• TXEMPTY: Transmit Empty
0 = Data remains in SSC_THR or is currently transmitted from TSR.
1 = Last data written in SSC_THR has been loaded in TSR and last data loaded in TSR has been transmitted.
• RXRDY: Receive Ready
0 = SSC_RHR is empty.
1 = Data has been received and loaded in SSC_RHR.
• OVRUN: Receive Overrun
0 = No data has been loaded in SSC_RHR while previous data has not been read since the last read of the Status
Register.
1 = Data has been loaded in SSC_RHR while previous data has not yet been read since the last read of the Status
Register.
• CP0: Compare 0
0 = A compare 0 has not occurred since the last read of the Status Register.
1 = A compare 0 has occurred since the last read of the Status Register.
• CP1: Compare 1
0 = A compare 1 has not occurred since the last read of the Status Register.
1 = A compare 1 has occurred since the last read of the Status Register.
• TXSYN: Transmit Sync
0 = A Tx Sync has not occurred since the last read of the Status Register.
1 = A Tx Sync has occurred since the last read of the Status Register.
11054A–ATARM–27-Jul-11
11054A–ATARM–27-Jul-11
31
23
15
7
SSC Status Register
30
22
14
SSC_SR
0xF0010040
Read-only
6
OVRUN
29
21
13
5
RXRDY
28
20
12
4
RXSYN
27
19
11
3
TXSYN
26
18
10
2
TXEMPTY
RXEN
CP1
25
17
9
1
SAM9X25
SAM9X25
TXRDY
TXEN
CP0
24
16
8
0
1029
1029

Related parts for SAM9X35