LM3S317-IQN20-A0T Luminary Micro, Inc., LM3S317-IQN20-A0T Datasheet - Page 344

no-image

LM3S317-IQN20-A0T

Manufacturer Part Number
LM3S317-IQN20-A0T
Description
Microcontroller
Manufacturer
Luminary Micro, Inc.
Datasheet
Pulse Width Modulator (PWM)
344
Reset
Reset
Type
Type
Bit/Field
31:12
11:10
PWMn Generator B Control (PWMnGENB)
9:8
7:6
5:4
3:2
1:0
RO
RO
31
15
0
0
Register 19: PWM0 Generator B Control (PWM0GENB), offset 0x064
counter, as well as the compare A and compare B pulses from the comparators. When the counter
is running in Down mode, only four of these events occur; when running in Up/Down mode, all six
occur. These events provide great flexibility in the positioning and duty cycle of the PWM signal
that is produced.
The PWM0GENB register controls generation of the PWM0B signal.
Each field can take on one of the values defined in Table 15-2 on page 343, which defines the
effect of the event on the output signal.
If a zero or load event coincides with a compare A or compare B event, the zero or load action is
taken and the compare A or compare B action is ignored. If a compare A event coincides with a
compare B event, the compare B action is taken and the compare A action is ignored.
control the generation of the PWMNB signal based on the load and zero output pulses from the
RO
RO
30
14
0
0
reserved
ActCmpBD
ActCmpBU
ActCmpAD
ActCmpAU
reserved
ActLoad
ActZero
Name
RO
RO
29
13
0
0
RO
RO
28
12
0
0
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RO
RO
27
11
ActCmpBD
0
0
R/W
RO
26
10
0
0
Reset
R/W
RO
25
ActCmpBU
0
9
0
0
0
0
0
0
0
0
Preliminary
R/W
RO
24
0
8
0
reserved
Description
Reserved bits return an indeterminate value, and should
never be changed.
The action to be taken when the counter matches
comparator B while counting down.
The action to be taken when the counter matches
comparator B while counting up. Occurs only when the
Mode bit in the PWMnCTL register (see page 334) is set
to 1.
The action to be taken when the counter matches
comparator A while counting down.
The action to be taken when the counter matches
comparator A while counting up. Occurs only when the
Mode bit in the PWMnCTL register is set to 1.
The action to be taken when the counter matches the load
value.
The action to be taken when the counter is 0.
R/W
RO
23
ActCmpAD
0
7
0
R/W
RO
22
0
6
0
R/W
RO
21
ActCmpAU
0
5
0
R/W
RO
20
0
4
0
R/W
RO
19
0
3
0
ActLoad
R/W
RO
18
0
2
0
R/W
RO
17
May 4, 2007
0
1
0
ActZero
R/W
RO
16
0
0
0