B – Command Line Interface
Set Config Command
B-32
switch
Initiates an editing session in which to change switch configuration settings. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
AdminState
BroadcastEnabled
InbandEnabled
DefaultDomainID
DomainIDLock
SymbolicName
R_A_TOV
E_D_TOV
PrincipalPriority
ConfigDescription
Parameter
Table B-10. Set Config Switch Parameters
Switch administrative state: online,
offline, or diagnostics. The default is
Online.
Broadcast. Enables (True) or disables
(False) forwarding of broadcast frames.
The default is True.
Inband management. Enables (True) or
disables (False) the ability to manage
the switch over an ISL. The default is
True.
Default domain ID. The default is 1.
Prevents (True) or allows (False)
dynamic reassignment of the
domain ID. The default is False.
Descriptive name. The default is
SANbox2.
Resource Allocation Timeout Value.
The number of milliseconds the switch
waits to allow two ports to allocate
enough resources to establish a link.
The default is 10000.
Error Detect Timeout Value. The
number of milliseconds a port is to wait
for errors to clear. The default is 2000.
The priority used in the FC-SW-2
principal switch selection algorithm. 1 is
high, 255 is low. The default is 254.
The name for the configuration. The
default is undefined.
Description
59021-06 A