threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its thresholds, and sampling interval one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the
and activating a configuration.
parameters. The switch will down a port if an alarm condition is not cleared within
three consecutive sampling intervals (by default 30 seconds). Reset the port to
bring it back online. An alarm is cleared when the threshold monitoring detects
that the error rate has fallen below the falling threshold.
FC-SW-2 Compliant
LegacyAddressFormat
Table B-10. Set Config Switch Parameters (Continued)
Parameter
”Config Command” on page B-7
Table B-11
describes the Set Config Threshold
Propagates just the active zone set
throughout the fabric ( True, compliant)
or the entire zoning database (False,
non-compliant). The default is True.
Available only when the FC-SW-2
Compliant parameter is False, this
parameter enables (True) or disables
(False) the use of legacy address
formating for interoperating with
non-FC-SW-2 switches. Refer to
”FC-SW-2 Compliant” on page
The default is False.
for information about saving
B – Command Line Interface
Description
Set Config Command
B-33.
B-33